Edoxaban in atrial fibrillation patients with established coronary artery disease: Insights from ENGAGE AF–TIMI 48

Author:

Zelniker Thomas A1,Ruff Christian T1,Wiviott Stephen D1,Blanc Jean-Jacques2,Cappato Riccardo3,Nordio Francesco1,Mercuri Michele F4,Lanz Hans5,Antman Elliott M1,Braunwald Eugene1,Giugliano Robert P1

Affiliation:

1. TIMI Study Group, Division of Cardiovascular Medicine, Brigham and Women’s Hospital and Harvard Medical School, Boston, USA

2. CHU de Brest Hôpital de la Cavale Blanche, Brest Cedex, France

3. Arrhythmia and Electrophysiology Research Center, IRCCS Humanitas Research Center, Milan, Italy

4. Daiichi Sankyo Pharma Development, Basking Ridge, USA

5. Daiichi Sankyo Europe GmbH, München, Germany

Abstract

Background: The relative efficacy and safety profile of the oral Factor Xa inhibitor edoxaban compared with warfarin in patients with atrial fibrillation and established coronary artery disease (CAD) has not been analyzed. Materials and methods: In the ENGAGE AF–TIMI 48 trial, two edoxaban regimens were compared with warfarin in 21,105 patients with atrial fibrillation and CHADS2 ⩾2. We analyzed the primary trial endpoints (efficacy: stroke or systemic embolic event, safety: International Society on Thrombosis and Haemostasis major bleeding) in patients with versus without CAD, and used interaction testing to assess for treatment effect modification. Results: The 4510 patients (21.4%) with known CAD were older, more likely male, on aspirin, with lower creatinine clearance and higher CHADS2 and HAS-BLED scores ( p <0.001 for each). Treatment with the higher-dose edoxaban regimen (versus warfarin) in patients with known CAD tended to have a greater reduction in stroke/systemic embolic event compared with patients without CAD (CAD: hazard ratio 0.65 (0.46–0.92) versus no CAD: hazard ratio 0.94 (0.79–1.12), p-INT 0.062) and also in myocardial infarction (CAD: hazard ratio 0.69 (0.49–0.98) versus no CAD: hazard ratio 1.24 (0.89–1.72), p-INT 0.017), while there was a similar reduction in bleeding irrespective of CAD status (hazard ratio 0.81 and 0.80, p-INT 0.97). Presence or absence of CAD did not modify the efficacy or safety profile of the lower-dose edoxaban regimen (versus warfarin). Conclusion: The reduction in ischemic events with the higher-dose edoxaban regimen versus warfarin was greater in patients with CAD, while bleeding was significantly reduced with edoxaban regardless of CAD status. The efficacy and safety profile of the lower-dose edoxaban regimen relative to warfarin was unaffected by CAD status.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Critical Care and Intensive Care Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3