Diagnostic accuracy of functional, imaging and biochemical tests for patients presenting with chest pain to the emergency department: A systematic review and meta-analysis

Author:

Iannaccone Mario12,Gili Sebastiano1,De Filippo Ovidio1,D’Amico Salvatore1,Gagliardi Marco1,Bertaina Maurizio1,Mazzilli Silvia1,Rettegno Sara1,Bongiovanni Federica1,Gatti Paolo1,Ugo Fabrizio2,Boccuzzi Giacomo G2,Colangelo Salvatore2,Prato Silvia2,Moretti Claudio1,D’Amico Maurizio1,Noussan Patrizia2,Garbo Roberto2,Hildick-Smith David3,Gaita Fiorenzo1,D’Ascenzo Fabrizio1

Affiliation:

1. Division of Cardiology, University of Turin, Italy

2. Division of Cardiology, S.G. Bosco Hospital, Italy

3. Brighton and Sussex University Hospitals NHS Trust, UK

Abstract

Background: Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined. Methods: Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included. Results: Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79–0.94) and 0.84 (0.74–0.9) vs 0.89 (0.78–0.94) and 0.83 (0.70–0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81–0.98) and specificity 0.90 (0.93–0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77–0.91) and specificity 0.92 (0.83–0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy. Conclusions: Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Critical Care and Intensive Care Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3