Abstract
We present the first case of iatrogenic hypothyroidism as a result of compounded thyroid hormone (T4/T3) therapy. The thyroid replacement was changed from 175 µg levothyroxine (LT4) to 57/13.5 µg compounded T4/T3 daily in order to improve the T3 level, despite normal thyroid-stimulating hormone (TSH). This resulted in clinical manifestations of hypothyroidism and high TSH level (150 µIU/mL). Six months later, the patient was referred to our clinic for abnormal pituitary magnetic resonance imaging. On reinitiating a physiologic dose of LT4, clinical and biochemical abnormalities resolved and the pituitary gland size decreased. Our case emphasizes the importance of using TSH level to gauge dose adjustments in primary hypothyroidism. Also, it underscores the current American Thyroid Association recommendation against routine use of compounded thyroid hormone therapy.