Device use errors with soft mist inhalers: A global systematic literature review and meta-analysis

Author:

Navaie Maryam12ORCID,Dembek Carole3,Cho-Reyes Soojin1,Yeh Karen1,Celli Bartolome R4

Affiliation:

1. Advance Health Solutions, LLC, New York, NY, USA

2. School of Professional Studies, Columbia University, New York, NY, USA

3. Global Health Economics and Outcomes Research, Sunovion Pharmaceuticals Inc., Marlborough, MA, USA

4. Chronic Obstructive Pulmonary Disease Center, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA

Abstract

Inhaled bronchodilators are the cornerstone of treatment for chronic obstructive pulmonary disease (COPD). Soft mist inhalers (SMIs) are devices that deliver bronchodilators. Although correct device use is paramount to successful medication delivery, patient errors are common. This global systematic literature review and meta-analysis examined device use errors with SMIs among patients with obstructive lung diseases. PubMed, EMBASE, PsycINFO, Cochrane, and Google Scholar were searched to identify studies published between 2010 and 2019 that met the following inclusion criteria: (a) English language; (b) a diagnosis of COPD, bronchitis, or emphysema; and (c) reported device use errors among adults receiving long-acting bronchodilator treatment with Respimat® SMI (i.e. Spiriva®, Stiolto®, Spiolto®, and Striverdi®). Descriptive statistics examined sociodemographics, clinical characteristics, and device use errors. Meta-analysis techniques were employed with random-effects models to generate pooled mean effect sizes and 95% confidence intervals (CIs) for overall and step-by-step errors. The I 2 statistic measured heterogeneity. Twelve studies ( n = 1288 patients) were included in this meta-analysis. Eighty-eight percent of patients had COPD, and most had moderate/very severe airflow limitation (Global Initiative for Chronic Obstructive Lung Disease spirometric stages II to IV). Aggregate results revealed that 58.9% (95% CI: 42.4–75.5; I 2 = 92.8%) of patients made ≥1 device use errors. Among 11 studies with step-by-step data, the most common errors were failure to (1) exhale completely and away from the device (47.8% (95% CI: 33.6–62.0)); (2) hold breath for up to 10 seconds (30.6% (95% CI: 17.5–43.7)); (3) take a slow, deep breath while pressing the dose release button (27.9% (95% CI: 14.5–41.2)); (4) hold the inhaler upright (22.6% (95% CI: 6.2–39.0)); and (5) turn the base toward the arrows until it clicked (17.6% (95% CI: 3.0–32.2)). Device use errors occurred in about 6 of 10 patients who used SMIs. An individualized approach to inhalation device selection and ongoing training and monitoring of device use are important in optimizing bronchodilator treatment.

Funder

Sunovion

Publisher

SAGE Publications

Subject

Pulmonary and Respiratory Medicine

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3