Trifecta and Carpentier Edwards aortic bioprostheses: Comparison of six years follow-up outcomes

Author:

Pfister Raymond1ORCID,Frey Vincent1ORCID,Kirsch Matthias1,Tozzi Piergiogio1,Delay Dominique12,Gunga Ziyad1,Prêtre René1,Niclauss Lars1ORCID

Affiliation:

1. Department of Cardiovascular Surgery, Lausanne University Hospital (CHUV), Lausanne, Switzerland

2. Department of Cardiac Surgery, Hopital du Valais, Sion, Switzerland

Abstract

Background To compare mid-term clinical outcomes and hemodynamic performance of the stented pericardial Trifecta bioprosthesis for surgical aortic valve replacement (AVR) with a technically comparable commonly used surgical bioprosthesis. Methods Data from consecutive patients implanted with the TF or the Carpentier Edwards Magna Ease valve were retrospectively analyzed. Primary analysis was performed on a propensity score–matched cohort. Primary endpoints included the composite of death or reoperation and structural valve deterioration. The comparison also included echocardiographic assessments at one-week post-AVR and at the last documented follow-up. Results Two propensity score–matched groups of 170 patients each were identified from the overall population ( n = 486). Incidence of postoperative mortality (2.9% vs. 7.1%, respectively, p = 0.08), and patient prosthesis mismatch (1.2% and 2.4%, p = 0.41) were similar. At mean follow-up of 5.84 (Trifecta) and 6.1 (Carpentier Edwards) years, the incidence of all-cause death/reoperation (15.3% vs. 15.9%, p = 0.88 for Trifecta and Carpentier Edwards, respectively) and structural valve disease (1.8% vs. 2.9%, p = 0.47) were similar. Overall, postoperative mean transvalvular pressure gradients were significantly lower in the Trifecta group than in the Carpentier Edwards group (7.7 ± 3.3 vs. 11.3 ± 3.6 mmHg, p < 0.01). Mean transvalvular gradient remained significantly lower through the last follow-up for small-sized Trifecta valves (19/21 mm; 10.5 ± 4.2 vs. 13.8 ± 5.9 mmHg, p = 0.039) but not for larger valves (10.3 ± 4.8 vs. 9.4 ± 3.5 mmHg, p = 0.31). Conclusion The Trifecta valve is a valuable alternative to the Carpentier Edwards valve in terms of safety, hemodynamic performance, and mid-term durability. Smaller-sized valves provide additional clinical benefits, given their persistent hemodynamic advantages through mid-term follow-up.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3