Interaction of heparin and protamine in presence of overdosage: in vitro study

Author:

Hanke Alexander A1ORCID,Severloh Ines12,Flöricke Felix1,Weber Christian F3,Lang Thomas4

Affiliation:

1. Department of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Germany

2. Department of Traumatology and Orthopedic Surgery, Allgemeines Krankenhaus Celle, Celle, Germany

3. Department of Anesthesiology and Intensive Care Medicine, Asklepios Clinic Hamburg-Wandsbek, Germany

4. Gerinnungsambulanz Südheide, Hohne, Germany

Abstract

Background Heparin is used for anticoagulation during cardiopulmonary bypass. After weaning from bypass, protamine is administered to neutralize the effects of heparin and thus reestablish hemostasis. Rotational thrombelastometry has been shown to discriminate between heparin and other impairing effects on coagulation. We analyzed the interaction of heparin and protamine under different conditions of overdosage in an in-vitro trial. Methods Blood samples were taken from 17 healthy volunteers, separated, and spiked in vitro with heparin, protamine for heparin neutralization, an overdosage of protamine, and two dosages of re-heparinization to evaluate heparin effects under the condition of protamine overdosage. All samples were analyzed in a standard ROTEM rotational thromboelastometry device after intrinsic activation with and without addition of heparinase. Coagulation time, maximum clot firmness, and clot formation time were recorded. Results Heparin led to prolongation of coagulation and clot formation times in the test without heparinase. Adequate protamine addition normalized the test, and overdosage of protamine led to significant prolongation of both times. Addition of heparin in the presence of protamine overdosage normalized these parameters. Conclusion We reconfirmed that the ROTEM device enables discrimination of the effects heparin and protamine on coagulation and detection of the coagulation-impairing effects of protamine overdosage. Furthermore, we were able to show a positive effect on coagulation times by heparin in the presence of protamine overdosage. Because this was an in-vitro study, these findings need to be confirmed in vivo, requiring further research.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3