Affiliation:
1. Department of Cardiology South Cleveland Hospital Middlesborough, Cleveland, England, UK
Abstract
We present an unusual complication caused by a dialysis catheter inserted through the internal jugular vein into the central venous system. The 49-year-old male patient developed a right atrial thrombus, which became infected with Staphylococcus aureus, resulting in septic pulmonary embolism and septicemic shock. The thrombus was excised on cardiopulmonary bypass. The patient made an uneventful recovery.
Subject
Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery
Cited by
13 articles.
订阅此论文施引文献