Sutureless valves versus aortic root enlargement for aortic valve replacement in small aortic annulus: A systematic review and pooled analysis

Author:

Agarwal Rajat1ORCID,Arnav Amiy2,Ranjan Ashis3,Mudgal Shiv4,Singh Dharmendra5

Affiliation:

1. Department of Cardiothoracic Surgery, All India Institute of Medical Sciences (AIIMS), Deoghar, Jharkhand, India

2. Department of Surgical Oncology, All India Institute of Medical Sciences (AIIMS), Deoghar, Jharkhand, India

3. Department of Cardiology, All India Institute of Medical Sciences (AIIMS), Deoghar, Jharkhand, India

4. College of Nursing, All India Institute of Medical Sciences (AIIMS), Deoghar, Jharkhand, India

5. Department of Radiotherapy, All India Institute of Medical Sciences (AIIMS), Deoghar, Jharkhand, India

Abstract

Background Very few studies provide direct comparisons between aortic root enlargement and sutureless valve implantation in patients with a small aortic annulus who underwent aortic valve replacement. This study aims to provide comparative outcomes between the two in such a subset of patients, through a systematic review and pool analysis. Methods The PubMed, Scopus and Embase databases were searched using the appropriate terms. The data from original articles mentioning aortic root enlargement and sutureless valves in a single or comparative study with another group of patients with a small aortic annulus were pooled and analyzed using descriptive statistics. Results Both cardiopulmonary bypass (68.4 vs. 125.03 min, p < 0.001) and aortic cross-clamp times were significantly shorter in the sutureless valve group, along with a concomitantly higher number of minimally invasive surgeries. The incidence of permanent pacemaker implantation (9.76% vs. 3.16%, p < 0.00001), patient prosthesis mis-match and paravalvular leak was significantly higher in the sutureless valve group. In comparison, the incidence of re-exploration for bleeding was higher in the aortic root enlargement group (5.27% vs. 3.16%, p < 0.02). The two groups had no differences in the duration of hospital stays or mortality. Conclusions Sutureless valves demonstrated a comparable hemodynamic outcome with aortic root enlargement in patients with a small aortic annulus. In addition to this, it greatly facilitated minimally invasive surgery. However, the high incidence of pacemaker implantation is still a concern for the widespread recommendation of sutureless valves, especially in young patients with a small aortic annulus.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3