Early- and mid-term outcomes of reinterventions for aortic bioprosthesis failure

Author:

Malvindi Pietro Giorgio12ORCID,Luthra Suvitesh1,Santarpino Giuseppe3,Ramadan Taha1,Hunduma Gabriel1,Olevano Carlo1,Ohri Sunil K1

Affiliation:

1. Wessex Cardiothoracic Centre, University Hospital Southampton, Southampton, UK

2. Department of Experimental and Clinical Medicine, Polytechnic University of Marche, Ancona, Italy

3. Cardiac Surgery Unit, Department of Experimental and Clinical Medicine, University "Magna Graecia" of Catanzaro, Catanzaro, Italy

Abstract

Background The aim of this study was to evaluate early- and mid-term results of our actual practice embedding redo aortic valve replacement and transcatheter procedures for aortic bioprosthetic failure. Methods Data for aortic valve reinterventions (redo surgical aortic valve replacement, isolated redo aortic valve replacement, and valve-in-valve transcatheter aortic valve implantation, transcatheter valve-in-valve procedure) were collected (2010–2019). Logistic regression analysis was performed to identify predictors favouring the choice of transcatheter against redo surgery. Cox analysis was used to study the association of preoperative variables with survival. Survival probabilities were calculated with Kaplan-Meier analysis and compared using a log-rank test. Results A total of 125 patients were included (redo surgical aortic valve replacement: 84 patients, valve-in-valve transcatheter aortic valve implantation: 41 patients). Median age was 74 [63–80] years, 58% of the patients were male and the median logistic EuroSCORE was 15 [8–26] %. There was no early mortality. Eighteen patients (redo surgical aortic valve replacement: 15, valve-in-valve transcatheter aortic valve implantation: 3) sustained at least one postoperative complication. At pre-discharge transthoracic echocardiogram, valve-in-valve transcatheter aortic valve implantation had significantly higher trans-prosthetic gradients (mean gradient: valve-in-valve transcatheter aortic valve implantation 18 mmHg vs. redo surgical aortic valve replacement 14 mmHg, p < 0.001). Overall survival probabilities were 94% and 73% at 1 year and 5 years, respectively. Previous coronary artery bypass surgery operation and age were independently associated with lower survival probabilities during the follow-up. Conclusions Redo surgical aortic valve replacement and valve-in-valve transcatheter aortic valve implantation are both safe and effective for aortic bioprosthetic failure. Further valve-in-valve data are needed to determine the haemodynamic performance of transcatheter prostheses and its impact on long-term outcomes.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3