Use of functional respiratory imaging to characterize the effect of inhalation profile and particle size on lung deposition of inhaled corticosteroid/long-acting β2-agonists delivered via a pressurized metered-dose inhaler

Author:

Van Holsbeke Cedric1,De Backer Jan2,Vos Wim2,Marshall Jonathan3

Affiliation:

1. FLUIDDA NV, Groeningenlei 132, 2550 Kontich, Belgium

2. FLUIDDA NV, Kontich, Belgium

3. Mundipharma International Ltd, Cambridge, UK

Abstract

Background: Functional respiratory imaging (FRI) uses three-dimensional models of human lungs and computational fluid dynamics to simulate functional changes within airways and predict the deposition of inhaled drugs. This study used FRI to model the effects of different patient inhalation and drug formulation factors on lung deposition of an inhaled corticosteroid/long-acting β2-agonist (ICS/LABA) combination, administered by a pressurized metered-dose inhaler. Methods: Three-dimensional models of the lungs of six patients with asthma (mean forced expiratory volume in 1 s, 83%), treated with an ICS/LABA, were included. FRI modelling was used to simulate (1) the effects on lung deposition of inhalation duration and particle size [fine particle fraction (FPF), proportion of particles <5 µm; and mass median aerodynamic diameter (MMAD), average size of inhalable particles]; (2) deposition of fluticasone propionate/formoterol (FP/FORM) 125/5 µg; and (3) how inhalation profiles and flow rates affected FP/FORM deposition. Results: Total lung depositions (TLDs) following 1-, 3- and 5-s inhalations were 22.8%, 36.1% and 41.6% (metered dose), respectively, and central-to-peripheral deposition (C:P) ratios were 1.81, 0.86 and 0.61, respectively. TLD increased with increasing FPF, from ~8% at 10% FPF to ~36% at 40% FPF (metered dose); by contrast, MMAD had little effect on TLD, which was similar across MMADs (1.5–4.5 µm) at each FPF. FP/FORM deposited throughout central and peripheral airways with gradual (sinusoidal) and sharp (rapid) inhalations. TLD ranged from 35.8 to 44.0% (metered dose) for gradual and sharp inhalations at 30 and 60 L/min mean flow rates. Conclusions: These data provide important insights into the potential effects of inhalation characteristics (inhalation profile and duration) and aerosol formulation (FPF) on lung deposition of inhaled therapies. FRI thus represents a useful alternative to scintigraphy techniques. Future FRI studies will further our understanding of the deposition of inhaled drugs and help improve the management of asthma.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3