Ultrasonography – a novel auxiliary interpretive approach for tuberculin-purified pure protein derivative skin test: a comparative study

Author:

Jiao Weijie1,Huang Yi2,Lei Ying2,Zhang Jun1,Yu Ming3ORCID

Affiliation:

1. The Department of Ultrasound, Xijing Hospital, The Fourth Military Medical University, Xi’an, Shaanxi, China

2. Department of Ultrasound, Xi’an Chest Hospital, Xi’an, Shaanxi, China

3. The Department of Ultrasound, Xijing Hospital, The Fourth Military Medical University, No.127 Changle West Road, Xi’an, Shaanxi 710032, China

Abstract

Background: The tuberculin-purified protein derivative (PPD) test is commonly used as a screening tool for tuberculosis (TB). However, the traditional judgment standard of the PPD test is influenced by subjective factors, which can lead to less accurate and intuitive test results. Objectives: To evaluate the accuracy of ultrasonography as a novel auxiliary judgment method for the tuberculin-PPD test and its clinical application. Design: This study was designed as a comparative study following the STROBE guidance. Methods: From February to May 2022, 208 patients with active tuberculosis infection were enrolled. Manual judgment and ultrasonography were employed in a double-blind-utilized manner, and the PPD examination results were recorded. Kappa statistic was performed to measure the concordance between the two diagnostic methods. Fisher’s exact test was used for the analyses of the PPD test results of all 208 active tuberculosis infection patients’ PPD results. Results: There was a significant difference between the two methods in the PPD result judgment ( p < 0.001), particularly in the positive ratio of the PPD test results, ( p < 0.05). Overall, 50 patients were determined as PPD positive based on manual judgment. However, only 24 patients’ PPD test results were determined as positive via ultrasonography. The remaining 26 patients should have been classified as strong positive but were misclassified as positive. The misdiagnosis ratio was 52% (26/50). Conclusion: Ultrasonography has superior accuracy to traditional manual judgment. Moreover, it does not rely on sophisticated clinical experience or training and can reveal subtle changes of the skin corresponding to each PPD test result providing intuitive results. In conclusion, ultrasonography can be used as an auxiliary interpretive approach for PPD test and has a promising future for clinical application.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3