Long-term efficacy and safety of the Dumon stent for treatment of benign airway stenosis

Author:

Lin Li-Qin1ORCID,Chen Di-Fei1,Wu Hong-Kai1,Chen Yu1,Zhong Chang-Hao1,Chen Xiao-Bo1,Tang Chun-Li1,Zhou Zi-Qing1ORCID,Li Shi-Yue2

Affiliation:

1. State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China

2. Department of Respiratory, State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, The First Affiliated Hospital of Guangzhou Medical University, 151 Yanjiang Road, Guangzhou 510120, Guangdong, China

Abstract

Background: The long-term efficacy of the Dumon stent in the treatment of benign airway stenosis is unclear. Objective: The objective of this study was to evaluate the long-term efficacy and safety of the Dumon stent in patients with benign airway stenosis. Methods: We retrospectively reviewed patients with benign airway stenosis who were treated with a Dumon stent at the First Affiliated Hospital of Guangzhou Medical University between March 2014 and October 2021. We included patients with successful removal of silicone stents after implantation. The clinical data and information on bronchoscopic interventional procedures and related complications were collected and analyzed. Results: Ninety-nine patients with benign airway stenosis were included. The stent was placed mainly in the trachea (44.4%) and left main bronchus (43.4%). The main type of stenosis was post-tuberculosis bronchial stenosis (57.6%). The overall cure rate was 60.6%. Stent-related complications included retention of secretions (70.7%), granuloma formation (67.7%), stent angulation (21.2%), and stent migration (12.1%). The stent was less effective for left main bronchus stenosis ( p = 0.012). Multivariate logistic regression analysis identified that stent placement for more than 13 months, a stent-intervention number of ⩽ 1 predicted a favorable outcome. Conclusion: The efficacy and safety of the Dumon stent for benign airway stenosis need improvement. The stent is less effective for left main bronchus stenosis; regular follow-up is required in such cases. Stent placement for > 13 months and no more than once stent intervention within a 6-month period were associated with a favorable outcome.

Funder

the Innovation team of respiratory diseases and regenerative medicine

Zhongnanshan medical foundation of Guangdong Province

the Grand Program on National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Pharmacology (medical),Pulmonary and Respiratory Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3