DEOXYRIBONUCLEIC ACID CYTOPHOTOMETRY OF STAINED HUMAN LEUKOCYTES II. THE MECHANICAL SCANNER OF CYDAC, THE THEORY OF SCANNING PHOTOMETRY AND THE MAGNITUDE OF RESIDUAL ERRORS

Author:

MAYALL BRIAN H.1,MENDELSOHN MORTIMER L.1

Affiliation:

1. Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104

Abstract

The mechanical scanner of CYDAC is a dual beam cytophotometer with a Nipkow scanning disc, analogue photometric circuits, digital conversion and accumulation of the photometric values and digital control of the scanning procedure. A measuring sequence involves object and clear field scans, and the final readout is virtually independent of fluctuations and heterogeneities in illumination and of variations in the size of the scanning apertures. Optical sources of error are analyzed both theoretically and experimentally as they apply to scanning cytophotometers. The effects of conical and polychromatic illumination, stray light and heterogeneous distribution of chromophore lead to negative averaging errors that are a function of optical density. The role of scan aperture size and optical resolution on distributional error is discussed and calculated in terms of three possible models. Non-absorptive phenomena, such as scattering and diffraction, lead to positive errors that are complementary, in a qualitative sense, to distributional error. In attempting to isolate these different errors experimentally, we show that measurements of the relative deoxyribonucleic acid stain content of human leukocytes are independent, within wide limits, of condenser and objective numerical aperture and of changes in absorptivity secondary to changes in wavelength. Where an adequate theory exists, these experimental results agree well with the theoretical predictions and, in any case, they indicate that for stained leukocytes the net effect of all optical errors must be less than 2%. Random measuring errors include both photon shot noise and errors associated with the geometry of the scanning disc. These errors contribute to an error of 1.2% among replicate measurements of leukocytes made under standard conditions. The previously reported differences in stain content among leukocyte types and among individual cells within types cannot be ascribed to either optical or instrumentation errors. Thus, the measured differences must reflect actual differences either in the amount or in the absorptivity of the stain.

Publisher

SAGE Publications

Subject

Histology,Anatomy

Cited by 65 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3