The use of closed intramedullary nailing fixation and drilling technique is a very common, safe and standard method for treating diaphyseal femoral fractures. However, it has several demerits such as high cutting forces and torque during drilling and this could cause high vibration and result in cracks, tool breakage and necrosis of the already fractured bone. This paper presents the measure of force, torque control and vibration absorber system for intra-operative tele-operated robotic-assisted femoral shaft drilling using air-controlled balloon damper experimentally, since bone is surrounded by soft tissues that can cause more severe injury to the tissue due to high traction force. Simulated femur bone and tissue are used for this experiment. A sensor-based model clamping system embedded with controlled pressurized air balloon to damp drilling vibration was developed; the drilling forces were monitored by the force sensor attached to the end robot effector, while the resulted vibration was measured by contact sensor during the entire surgical drilling. Forces and vibration caused by drilling forces acting on the bone at varying damper pressure at varying spindle drill speed were obtained using (EMS 309 data acquisition and then the data were processed using MATLAB R2015b. The vibration results were processed with wavelet packet transform (WPT) using Fast Fourier transform to analyze the vibration signals, frequencies and amplitude of the vibration. This modeled control system is a good concept, results clearly justify that soft clamping fixation system can be employed to reduce force, torque and vibration without causing harm to the delicate surrounding tissues. This control measures can provide surgeons with real-time information which can assist them in repositioning and repair of fracture bone within control and safe margins. It is believed that this idea will have greater future developmental prospect.

Publisher

SAGE Publications

Subject

Instrumentation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3