Affiliation:
1. Department of Engineering Science, University of Oxford, Park Rd, Oxford OX1 3PJ, UK
Abstract
An experimental and theoretical investigation has been undertaken on a viscous flowmeter, with both steady and unsteady flow. The steady flow analysis quantifies the nonlinear effects of entry and exit losses, development length effects and compressibility effects. The steady flow analysis and experiments show that the pressure drop has a quadratic response to flowrate, but that for practical applications a linear approximation will lead to an error of less than 1%. The unsteadyflow experiments show that it is necessary to integrate the instantaneous flow over a whole number of cycles, in order to obtain reliable values of the mean flow. An analysis of unsteady viscous flow has been used to show how the instantaneous pressure difference measured across the viscous flowmeter can be analysed to give the instantaneous volume flow rate.
Reference20 articles.
1. A double-refraction method of detecting turbulence in liquids
2. Bircumshaw, L.L., and Stott, V.H. 1929. 'Viscosity of Gases'. In International Critical Tables, Vol 5, pp 1-6. McGraw-Hill .
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献