Influence of venous reservoir level on microbubbles in cardiopulmonary bypass

Author:

Nielsen PF1,Funder JA2,Jensen MØ3,Nygaard H4

Affiliation:

1. Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Skejby, Denmark

2. Aarhus University Hospital, Skejby, Denmark

3. Department of Biomedical Engineering, Engineering College of Aarhus, Denmark

4. Biomedical Engineering, Aarhus University Hospital, Skejby, Denmark

Abstract

Patients undergoing open-heart surgery may, post-operatively, suffer from neurological disorders due to microbubbles created during extracorporeal circulation. Venous air is not completely removed in open hard-shell venous reservoirs. We, therefore, investigated the relationship between venous reservoir blood level and the amount of microbubbles in different commercially available reservoirs for comparison and determination of safe level. An in vitro flow loop with a heart-lung machine was used to compare three different reservoirs (Maquet, Sorin and Medtronic) at different levels. Microbubbles were measured after the reservoir and after the arterial filter with a GAMPT BCC200 detector. Microbubble count and volume were significantly higher with decreasing reservoir level ( p = 0.014), but not as much as earlier studies have shown. Reducing the level from 1000 ml to 250 ml resulted in a 12.4% increase in bubble volume after the reservoir and 40.2% after the arterial filter. There was an almost linear trend towards more bubble volume with decreasing reservoir level (R2 = 0.98-0.83). There was a significant difference in microbubbles between the 3 tested reservoirs, up to 32.6%, p < 0.001 measured after the reservoir. Bubble volume from the Sorin reservoir was markedly lower after the arterial filter than from the Medtronic and Maquet reservoirs (up to 60 times p < 0.001). A lower reservoir level results in a moderate rise in microbubbles passing the reservoir. The minimum levels recommended by the manufacturers are safe. There was a significant difference in bubbles between the different reservoirs, especially after the arterial filter.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3