Intra-aortic balloon pumping increases renal blood flow in patients with low left ventricular ejection fraction

Author:

Sloth E1,Sprogøe P2,Lindskov C1,Hørlyck A3,Solvig J3,Jakobsen CJ1

Affiliation:

1. Department of Anesthesia & Intensive Care Medicine, Aarhus University Hospital, Aarhus N, Denmark

2. Department of Cardiothoracic Surgery, Aarhus University Hospital, Aarhus N, Denmark

3. Department of Radiology, Aarhus University Hospital, Aarhus N, Denmark

Abstract

Intra-aortic balloon pumping (IABP) has, for decades, been one of the key treatment modalities following impaired cardiac function after cardiac surgery. IABP increases cardiac output, decreases oxygen consumption of the heart and relieves the left ventricle. However, a number of complications have been reported in connection with IABP treatment. Only a few studies have evaluated renal blood flow and the purpose of this prospective study was to evaluate whether renal blood flow was affected by IABP treatment in high-risk patients. After approval from the county ethical committee and informed consent, seven consecutive patients with low left ventricular ejection fraction and scheduled for preoperative IABP treatment were allocated to the study. Assessment of renal blood flow was based on ultrasound spectral Doppler estimation of the flow velocity profiles in the interlobar kidney arteries. The result was described as balloon index (BI), which is maximal systolic velocity divided by the temporal mean velocity. Typical velocity profiles were demonstrated in all patients before, during and after IABP. BI measurement changed with time (p <0.05). BI was lower during IABP compared to both pre-IABP and post-IABP (p <0.025), indicating a higher renal blood flow. No statistically significant changes were seen in s-creatinine or creatinine clearance. Assuming unchanged diameter of kidney arteries and no considerable decrease in renal resistance and/or compliance, we conclude that the interlobar renal blood flow was significantly increased during IABP treatment, measured by ultrasound Doppler technique, but without a simultaneously significant change in creatinine clearance.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3