Hemoglobin trigger and approach to red blood cell transfusions during veno-venous extracorporeal membrane oxygenation: the international TRAIN-ECMO survey

Author:

Martucci Gennaro1ORCID,Grasselli Giacomo23,Tanaka Kenichi4,Tuzzolino Fabio5,Panarello Giovanna1,Schmidt Matthieu67,Bellani Giacomo89,Arcadipane Antonio1

Affiliation:

1. Department of Anesthesia and Intensive Care, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy

2. Department of Pathophysiology and Transplantation, School of Medicine and Surgery, University of Milan, Milan, Italy

3. Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy

4. Department of Anesthesiology, University of Maryland, Baltimore, MD, USA

5. Research Office, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy

6. Institute of Cardiometabolism and Nutrition, Sorbonne Universités, UPMC Univ Paris 06, Paris, France

7. Medical Intensive Care Unit, Assistance Publique-Hôpitaux de Paris, Pitié-Salpêtrière Hospital, Paris, France

8. Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy

9. Department of Emergency and Intensive Care, San Gerardo Hospital, Monza, Italy

Abstract

Introduction: Optimal red blood cell transfusion practice during veno-venous extracorporeal membrane oxygenation (VV ECMO) is still under debate. This survey aimed to assess the Hb trigger (also comparing with other critically ill patients) and major physiologic determinants considered for transfusions during veno-venous extracorporeal membrane oxygenation. Methods: Voluntary Web-based survey, endorsed by the European Society of Intensive Care Medicine, conducted among VV ECMO pratictioners worldwide. Results: A total of 447 respondents worldwide answered the questionnaire: 277 (61.9%) from Europe, 99 (22.1%) from North America, 36 (8.2%) from Asia and Oceania, and 35 (7.8%) from Central and South America. Among the respondents, 59.2% managed less than 12 venous extracorporeal membrane oxygenation runs/year, 19.4% between 12 and 24 runs/year, and 21.4% more than 24 runs/year. Of the respondents, 54.4% do not use a predefined Hb trigger in veno-venous extracorporeal membrane oxygenation, and, while the rate of adoption of a defined trigger varied worldwide, the effective value of Hb did not differ significantly among macro-regions. In patients on veno-venous extracorporeal membrane oxygenation, the Hb trigger to initiate red blood cell transfusion, was higher than in other critically ill patients: 9.1 ± 1.8 g/dL versus 8.3 ± 1.7 g/dL, p < 0.01. The Hb trigger was lower in centers with more than 24 venous extracorporeal membrane oxygenation runs/year (8.4 mg/dL (95% CI: 7.7-8.9)); (8.9 mg/dL (95% CI: 8.2-9.7)) in centers with between 12 and 24 venous extracorporeal membrane oxygenation runs/year; and (9.6 mg/dL (95% CI: 9.1-10.0)) in centers with fewer than 12 venous extracorporeal membrane oxygenation runs/year (p < 0.01). Several and variable adjunctive parameters are considered in cases of uncertainty for transfusion: the principal are hemodynamic status, SvO2, lactates, and fluid balance. Conclusion: Although the use of a predefined Hb trigger is still under-adopted among centers with low or median extracorporeal membrane oxygenation case volume, the majority of respondents use a higher Hb trigger for veno-venous extracorporeal membrane oxygenation patients compared with other critically ill patients. Higher volume centers tolerate lower Hb levels.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3