Affiliation:
1. Department of Cardiac Surgery, Heart Center, HELIOS Clinic, University Hospital Leipzig, Leipzig, Germany
Abstract
Introduction:Cardiopulmonary bypass surgery is accompanied by an inflammatory response and pulmonary dysfunction that renders patients vulnerable to postoperative complications. The majority of studies investigating the inflammatory response in cardiopulmonary bypass focus on cytokine measurements. This study investigated the early response of peripheral blood cell types and early changes in lung tissue in on-pump versus off-pump cardiopulmonary bypass surgery.Methods:Landrace pigs were assigned to the following groups (n = 6 per group): 1. off-pump cardiopulmonary bypass, 2. conventional cardiopulmonary bypass, 3. heparin-coated cardiopulmonary bypass, 4. surface-reduced cardiopulmonary bypass, and 5. surface-reduced cardiopulmonary bypass plus lung perfusion. Surgery was performed under mild hyperthermia (32°C), with 90-minute ischemia and 180-minute reperfusion. Histological and flow cytometric analyses were performed.Results:Lung water content increased during reperfusion in heparin-coated (84.63 ± 2.99%) compared to conventional cardiopulmonary bypass (76.33 ± 4.56%, p = 0.04). Alveolar septal thickness increased during ischemia at heparin-coated (p < 0.01) and surface-reduced cardiopulmonary bypass plus lung perfusion (p = 0.05). Tumor necrosis factor expression increased significantly (p < 0.01) in peribronchial, perivascular, and peripheral lung areas in all on-pump groups, but not in off-pump cardiopulmonary bypass. The usage of heparin-coated cardiopulmonary bypass led to increased percentages of CD3+CD4+(p = 0.03) and CD3+CD8+(p = 0.01) T cells compared to an uncoated device. Natural killer and mature B lymphocytes decreased at conventional and surface-reduced cardiopulmonary bypass plus lung perfusion. Activated granulocytes and macrophages increased at conventional cardiopulmonary bypass and heparin-coated cardiopulmonary bypass.Conclusion:Off-pump cardiopulmonary bypass induces less immunological response and lung injury than on-pump surgery. The reduction of cardiopulmonary bypass surface reduces the inflammatory immune response induced by cardiopulmonary bypass. Lung perfusion of surface-reduced cardiopulmonary bypass diminished the extravasation caused by surface reduction of the cardiopulmonary bypass.
Subject
Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献