Differences of early immunological responses in on-pump versus off-pump cardiac surgery

Author:

Lehmann Sven1,Dieterlen Maja-Theresa1ORCID,Flister Anja1,Klaeske Kristin1,Jawad Khalil1,Garbade Jens1,Borger Michael A1,Kostelka Martin1

Affiliation:

1. Department of Cardiac Surgery, Heart Center, HELIOS Clinic, University Hospital Leipzig, Leipzig, Germany

Abstract

Introduction:Cardiopulmonary bypass surgery is accompanied by an inflammatory response and pulmonary dysfunction that renders patients vulnerable to postoperative complications. The majority of studies investigating the inflammatory response in cardiopulmonary bypass focus on cytokine measurements. This study investigated the early response of peripheral blood cell types and early changes in lung tissue in on-pump versus off-pump cardiopulmonary bypass surgery.Methods:Landrace pigs were assigned to the following groups (n = 6 per group): 1. off-pump cardiopulmonary bypass, 2. conventional cardiopulmonary bypass, 3. heparin-coated cardiopulmonary bypass, 4. surface-reduced cardiopulmonary bypass, and 5. surface-reduced cardiopulmonary bypass plus lung perfusion. Surgery was performed under mild hyperthermia (32°C), with 90-minute ischemia and 180-minute reperfusion. Histological and flow cytometric analyses were performed.Results:Lung water content increased during reperfusion in heparin-coated (84.63 ± 2.99%) compared to conventional cardiopulmonary bypass (76.33 ± 4.56%, p = 0.04). Alveolar septal thickness increased during ischemia at heparin-coated (p < 0.01) and surface-reduced cardiopulmonary bypass plus lung perfusion (p = 0.05). Tumor necrosis factor expression increased significantly (p < 0.01) in peribronchial, perivascular, and peripheral lung areas in all on-pump groups, but not in off-pump cardiopulmonary bypass. The usage of heparin-coated cardiopulmonary bypass led to increased percentages of CD3+CD4+(p = 0.03) and CD3+CD8+(p = 0.01) T cells compared to an uncoated device. Natural killer and mature B lymphocytes decreased at conventional and surface-reduced cardiopulmonary bypass plus lung perfusion. Activated granulocytes and macrophages increased at conventional cardiopulmonary bypass and heparin-coated cardiopulmonary bypass.Conclusion:Off-pump cardiopulmonary bypass induces less immunological response and lung injury than on-pump surgery. The reduction of cardiopulmonary bypass surface reduces the inflammatory immune response induced by cardiopulmonary bypass. Lung perfusion of surface-reduced cardiopulmonary bypass diminished the extravasation caused by surface reduction of the cardiopulmonary bypass.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3