Introduction: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system (“Dihead CPB”) for application during coronary artery bypass grafting (CABG) and valve surgery. To strive for minimal hemolysis during Dihead CPB, we compared the hemolysis caused by three different suction systems and performed a clinical study with the newly applied suction system. Materials & Methods: We evaluated the hemolysis caused by roller-pump suction, the SmartSuction® Harmony® and wall suction systems with respect to suction speed and compared the systems by means of in vitro studies. A clinical study was also performed on 15 volunteers to assess hemolysis and the adequacy of the newly applied suction system with Dihead CPB. Results: Pressure inside the suction cannula was −22.5 ± 0.1 mmHg at a maximum flow of 1.5 L/min for roller-pump suction and −43.4 ± 0.1 mmHg at −150 mmHg of the set vacuum pressure of wall suction. With the SmartSuction, the pressure inside the cannula varied from −76.3 ± 1.0 to −130.3 ± 1.5 mmHg, depending on suctioning conditions. Suction speed (to suction 50 ml of blood) was fastest with the SmartSuction (69.7 ± 3.58 s) whereas, with roller suction, it was 117.3 ± 8.47 s and with wall suction 96.9 ± 7.10 s. The SmartSuction had the highest hemolysis rate (2.00 ± 0.33%) vs. 0.61 ± 0.10% for roller suction and 0.41 ± 0.11% for wall suction (p<0.001). The clinical study with wall suction showed no significant increase in plasma free hemoglobin during or after CPB compared with before surgery. Conclusions: Wall suction had less hemolysis than roller suction or the SmartSuction in the in vitro study and the clinical study with wall suction showed efficient suction speed and acceptable hemolysis, suggesting that Dihead CPB with wall suction is feasible for CABG.

Funder

Shinshu University Hospital Grant

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3