Comparison of three autotransfusion devices for utilization in the pediatric population

Author:

Melchior Richard W1ORCID,Dreher Molly1,Shade Brandon1ORCID,Chappell Alexander1,Fisher Douglas1,Rosenthal Tami1

Affiliation:

1. Department of Perfusion Services, Cardiac Center, Children’s Hospital of Philadelphia, Philadelphia, PA, USA

Abstract

Introduction: A device that may help attenuate the amount of homologous blood product given to pediatric cardiac surgical patients is the autotransfusion device. Three separate autotransfusion devices were selected for evaluation. The Sorin Xtra, Fresenius Continuous Autotransfusion System Plus (CATS*plus), and the Fresenius Continuous Autotransfusion System Smart (CATSmart) were evaluated based on the mechanical processes of each device, hematocrit value of the salvaged packed red cell product, time of processing, and the advantageous accessories with each device. Methods: Each of the autotransfusion devices were used to collect salvageable blood from the surgical field as well as to process residual blood from the cardiopulmonary bypass circuit after decannulation. The cell salvage process was performed in accordance with the manufacturer’s instructions for use and the recommended settings for processing and washing. The Sorin Xtra device had the 55 mL bowl set up for all cases, while the Fresenius continuous autotransfusion systems utilized the standard disposable for each device. Results: Each cell salvage device was employed during 30 pediatric cardiac surgery procedures, and data for each device, was broken down into four groups based on patient weight (0-10, 10-20, 20-40, and >40 kg). For all patient sizes, the Sorin Xtra tended to produce the greatest volume of cell saver product (55-825 mL) as compared to the CATS*plus and CATSmart devices (7-550 mL and 0-860 mL, respectively). The Continuous Autotransfusion System Smart tended to produce the highest hematocrit product, ranging from 44 to 81%. Discussion: Through this evaluation, it was determined the continuous autotransfusion systems provided the highest hematocrit with the lowest recovered packed red cell volume, while the Sorin Xtra packed red cell product showed to have a lower hematocrit with a larger packed red cell volume. Each device proved effective within our pediatric population.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3