Haemocompatibility of membrane and bubble oxygenators

Author:

Pearson D.T.1,McArdle B.1

Affiliation:

1. Freeman Hospital, Newcastle-upon-Tyne

Abstract

During clinical hypothermic cardiopulmonary bypass (CPB), the haemocompatibility of six groups of membrane oxygenators (Cobe CML2, Shiley M2000, Maxima, Bard HF4000, Bard HF5000, Capiox E has been studied in 60 patients having open-heart surgery. A standardized anaesthetic and perfusion protocol was used, during which the abilityof the perfusionist to achieve target blood gas values (PaO2 20kPa and PaCO2 5.3kPa: alpha-stat) using inline electrodes was assessed. Haemocompatibility was evaluated by measurement of platelet numbers and function, betathromboglobulin (BTG), plasma haemoglobin, complement (C3a des Arg) and white blood cell (WBC) count pre- and post-CPB. Platelet and WBC numbers were also measured every five minutes throughout CPB. All oxygenators allowed the perfusionist to control blood gases adequately to prescribed levels. There were only minor differences in the degree and pattern of platelet depletion, reduction in platelet aggregation, elevation of BTG and C3a des Arg observed between oxygenator groups, which did not appear to be influenced by membrane type (flat plate versus hollow fibre). The membrane oxygenator haematological data was amalgamated with that obtained in previous clinical studies using membrane and bubble oxygenators (Cobe CML, Polystan Venotherm, Harvey H 1700, Bentley BIO-10, Bentley 1 0B, Bentley 1 OPlus, Gambro 10 and Shiley S100A HED) in which a similar evaluation protocol was employed. Comparison of the percentage change in platelet count when the pre- and post-CPB values were compared, demonstrated statistically significantly less platelet depletion (p <0.001 ) in the membrane oxygenator groups (-0.2 ± 8.3%) when compared to the bubble oxygenator groups (-21.7 ± 8.7%). A significantly lower percentage rise in BTG was also observed in the membrane oxygenator group when compared to the bubble oxygenator groups (p <0.001 ). All oxygenator groups showed elevation of both WBC count and plasma haemoglobin with a nonspecific fall in platelet aggregation over the period of bypass but no significant differences could be found between the two types of oxygenator. Membrane oxygenators, when compared to bubble oxygenators, exhibit lower GME production and improved haemocompatibility and allow superior blood gas control. Membrane oxygenators manifestly must be the oxygenator type of choice for clinical CPB.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3