In vitro clearance of dexmedetomidine in extracorporeal membrane oxygenation

Author:

Wagner D1,Pasko D2,Phillips K3,Waldvogel J4,Annich G5

Affiliation:

1. Pharmacy/Anesthesiology, University of Michigan Hospitals and Health Systems, Ann Arbor, MI, USA

2. C&W Administration, University of Michigan Hospitals and Health Centers, Ann Arbor, MI, USA

3. Geriatric Research Education and Clinical Center, VA Ann Arbor Healthcare System, Ann Arbor, MI, USA

4. Extracorporeal Life Support, University of Michigan Hospitals and Health Centers, Ann Arbor, MI, USA

5. Pediatric Critical Care Medicine, University of Michigan Hospitals and Health Centers, Ann Arbor, MI, USA

Abstract

Dexmedetomidine (DMET) is a useful agent for sedation, both alone and in combination with other agents, in critically ill patients, including those on extracorporeal membrane oxygenation (ECMO) therapy. The drug is a clonidine-like derivative with an 8-fold greater specificity for the alpha 2-receptor while maintaining respiratory and cardiovascular stability. An in vitro ECMO circuit was used to study the effects of both “new” and “old” membrane oxygenators on the clearance of dexmedetomidine over the course of 24 hours. Once primed, the circuit was dosed with 840 μg of dexmedetomidine for a final concentration of 0.9 μg/ml. Serial samples, both pre- and post-oxygenator, were taken at 5, 60, 360, and 1440 minutes. Concentrations of the drug were expressed as a percentage of the original concentration remaining at each time point, both for new and old circuits. The new circuits were run at a standard flow for 24 hours, after which time the circuit was considered old and re-dosed with dexmedetomidine and the trial repeated. Results show that dexmedetomidine losses occur early in the circuits and then continue to decline. Initial losses in the first hour were 11+-65% and 59-73% pre- and post-oxygenator in the new circuit and 36-50% and 42-72% in the old circuit. The clearance of the drug through the membrane oxygenator exhibits no statistical difference between pre and post or new and old circuits. Dexmedetomidine can be expected to exhibit concentration changes during ECMO therapy. This effect appears to be more related to adsorption to the polyvinyl chloride (PVC) tubing rather than the membrane oxygenator. Dosage adjustments during dexmedetomidine administration during ECMO therapy may be warranted in order to maintain adequate serum concentrations and, hence, the desired degree of sedation.*(Lack of equilibrium)

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3