Outcomes comparison of 5 coated cardiopulmonary bypass circuits versus an uncoated control group of patients undergoing cardiac surgery

Author:

Marcoux J.1,Sohn N.2,McNair E.2,Rosin M.2,Smith G.2,Lim H.2,Mycyk T.2,Meng Q.2

Affiliation:

1. Department of Clinical Perfusion, Cardiovascular Surgery and Clinical Chemistry, Royal University Hospital, Saskatoon, Saskatchewan, Canada,

2. Department of Clinical Perfusion, Cardiovascular Surgery and Clinical Chemistry, Royal University Hospital, Saskatoon, Saskatchewan, Canada

Abstract

Attenuated inflammatory response and decreased platelet activation have been claimed repeatedly when biocompatible circuits are used for cardiopulmonary bypass. We evaluated five Health Canada approved biocompatible circuit coatings (BCC) against an un-coated control group to determine their effectiveness in improving post-operative outcomes. Patients were assigned to the Control group or one of the 5 coated circuit groups: 40 Control; 33 Trillium; 32 Phisio; 34 Bioline; 33 X; and 11 GBS. Measured outcomes included: ventilator time; ICU time; post-operative chest tube drainage and transfusion volume; high sensitivity C-reactive protein (hsCRP); tau protein; and pre- and 72-hour post-operative anti-saccadic eye movement test comparisons. Results: 183 patients were enlisted into the study. One arm of the study (GBS) was abandoned after 11 patients on account of inconsistent pressure excursions within the oxygenator and the excessive consumption of platelets necessitating transfusion. Patients in the X-coated group had significantly longer ventilator and intensive care unit (ICU) time compared to the three remaining coated circuit study groups. Though not significant, patients in the X group also demonstrated the highest post-operative chest tube losses, the most platelet transfusions, the highest tau protein levels and the lowest post-operative anti-saccadic eye movement test (ASEMT) results compared to the three remaining coated groups. The patients in the Trillium, Bioline and Phisio groups showed an improvement in ventilator and ICU time relative to the Control group. The diabetic patients in the Trillium, Bioline and Phisio groups showed an improvement in bleeding relative to the diabetic patients in the Control group. Conclusion: We compared all 5 coated circuits approved for clinical use in Canada against an uncoated control circuit. Three of the 5 coated circuits (Trillium, Phisio and Bioline BCC) were found to improve ventilator and ICU time compared to Control. Further studies are indicated to validate these results and their impact upon approval criteria, purchasing choices and safe clinical practice, especially as applied to higher risk diabetic patients.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3