Clinical evaluation of the Bentley Univox membrane oxygenator

Author:

Nowak J.1,Pols G.1,Brands W.2,Rosseel P.3

Affiliation:

1. Department of Extracorporeal Circulation, de Klokkenberg Medical Centre, Breda NL

2. Department of Cardiopulmonary Surgery de Klokkenberg Medical Centre, Brede, NL

3. Department of Anaesthesiology, de Klokkenberg Medical Centre, Breda, The Netherlands

Abstract

This paper reports a clinical evaluation of Bentley's new Univox membrane oxygenator (Bentley Laboratories, Irvine, California). In this new device, the blood flow path is outside the fibre, the incorporated heat exchanger consists of a 22-channel stainless-steel bellows, and the polypropylene fibres are woven into fibre ribbons and wound into each of the bellows channels. In this way, heat and gas transfers take place simultaneously. The priming volume has been reduced to 220ml and the membrane has an effective surface area of 1.6m2. A BMR 1900 collapsible reservoir (Bentley Laboratories, Irvine, California) was used as a venous reservoir. Ten consenting patients undergoing elective coronary artery bypass surgery were perfused with this new oxygenator. BSA was between 1.7 and 2.11 m2; mean BSA was 1.81. Minimum priming was 1200ml. The blood-gas results were all within or close to the normal range used in our institution. Acid-base management was performed using alpha-stat regulation and no problems occurred in this series of patients. Average pO2was 155mmHg±53 with a mean O2transfer of 90.7ml and a maximum of 185ml. The heat exchange performance was very good, with a mean coefficient of heat exchange of 0.54±0.11 and a maximum of 0.87.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Reference4 articles.

1. Iatridis A. Ex vivo evaluation of prototype oxygenators applying guidelines of AAMI draft standards. In: Hagl S, Klövekom WP, Mayr N, Sebening F eds. Thirty years of extracorporeal circulation. Munich: Carl Gerber , 1984: 453-61.

2. STUDIES IN SERUM ELECTROLYTES

3. CALCULATION OF HEMOGLOBIN FROM BLOOD SPECIFIC GRAVITIES

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3