Albumin in the cardiopulmonary bypass prime: how little is enough?

Author:

Palanzo David A1,Zarro Debra L2,Montesano Ralph M2,Manley Norman J2

Affiliation:

1. Lehigh Valley Hospital, Allentown, Pennsylvania,

2. Lehigh Valley Hospital, Allentown, Pennsylvania

Abstract

Previous studies have demonstrated high transoxygenator pressures with noncoated hollow-fiber membrane oxygenators. These reports have been associated with dramatic platelet count drops during cardiopulmonary bypass (CPB). It has also been shown that adding human albumin to the prime of the bypass circuit reduces, if not eliminates, these problems. This study was conducted to determine what is the smallest amount of albumin added to the prime that will still display its protective effects. Eighty patients undergoing nonemergency open-heart surgery were randomly divided into four groups. Groups I and II received the Sarns Turbo 440 oxygenator with 0.0375 g of albumin/100 ml of prime and 0.125 g of albumin/100 ml of prime, respectively, added to the pump prime. Groups III and IV received the Medtronic Maxima-PRF oxygenator with 0.0375 g of albumin/100 ml of prime and 0.125 g of albumin/100 ml of prime, respectively, added to the pump prime. Pre-CPB, on CPB (15-20 min after the initiation of bypass) and warming hemoglobin, hematocrit and platelet counts were drawn on all patients. Net platelet count drop, which accounted for hemodilutional effects, was calculated for all specimens and compared to previous results obtained from the test oxygenators without albumin in the prime. The net platelet count drops for the study groups were as follows: • Sarns oxygenator with no albumin in the prime = 11.8 ± 12.5%; • Sarns oxygenator with 0.0375 g of albumin/100 ml prime = -3.7 ± 10.8%; • Sarns oxygenator with 0.125 g of albumin/100 ml prime = -2.0 ± 12.6%; • Medtronic oxygenator with no albumin in the prime = 20.1 ± 14.5%; • Medtronic oxygenator with 0.0375 g albumin/100 ml prime = -6.9 ± 8.7%; and • Medtronic oxygenator with 0.125 g albumin/100 ml prime = -14.0 ± 12.4%. Our results illustrate that adding as little as 0.0375 g albumin/100 ml prime (3 ml of 25% solution/2000 ml of prime) to the pump prime illicits the beneficial effects of surface coating on platelet loss during CPB.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3