Assessment of cardiac load-responsiveness in veno-arterial extracorporeal life support: A case series

Author:

Cornelisse Y1ORCID,Weerwind PW1,Bol ME23,Simons AP4

Affiliation:

1. Department of Extra-Corporeal Circulation and Cardiothoracic Surgery, Maastricht University Medical Centre, Maastricht, Netherlands

2. Department of Intensive Care Medicine, Maastricht University Medical Centre, Maastricht, Netherlands

3. School of Nutrition and Translational Research in Metabolism, Maastricht University Medical Centre, Maastricht, Netherlands

4. Advanced Extracorporeal Therapies - perfusion services, training & education, Landgraaf, the Netherlands

Abstract

Introduction Well-timed explant of veno-arterial extracorporeal life support (V-A ECLS) depends on adequate assessment of cardiac recovery. Often, evaluation of cardiac recovery consists of reducing support flow while visualizing cardiac response using transoesophageal echocardiography (TEE). This method, however, is time consuming and based on subjective findings. The dynamic filling index (DFI) may aid in the quantitative assessment of cardiac load-responsiveness. The dynamic filling index is based on the relationship of support flow and pump speed, which varies with varying hemodynamic conditions. This case series intends to investigate whether the DFI may support TEE in facilitating the assessment of cardiac load-responsiveness. Methods Measurements for DFI-determination were performed in seven patients while simultaneously assessing ventricular function by measuring the aortic velocity time integral (VTI) using TEE. Measurements consisted of multiple consecutive transient speed manipulations (∼100 r/min) during weaning trials, both at full support and during cardiac reloading at reduced support. Results The VTI increased between full and reduced support in six weaning trials. In five of these trials DFI decreased or remained equal, and in one case DFI increased. Of the three trials in which VTI decreased between full and reduced support, DFI increased in two cases and decreased in one case. Changes in DFI, however, are mostly smaller than the detection threshold of 0.4 mL/rotation. Conclusion Even though current level of accuracy of the parameter requires further investigation to increase reliability and possibly predictability, DFI seems likely to be a potential parameter in supporting TEE for the assessment of cardiac load-responsiveness.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370