The use of balanced HES 130/0.42 during complex cardiac surgery; effect on blood coagulation and fluid balance: a randomized controlled trial

Author:

Schramko A1,Suojaranta-Ylinen R1,Niemi T1,Pesonen E1,Kuitunen A2,Raivio P3,Salmenperä M1

Affiliation:

1. Department of Anaesthesiology and Intensive Care Medicine, Helsinki University Hospital, Melahti Hospital, Helsinki, Finland

2. Department of Intensive Care, Tampere University Hospital, Tampere, Finland

3. Department of Cardiothoracic Surgery, Helsinki University Hospital, Meilahti Hospital, Helsinki, Finland

Abstract

Introduction: Colloids and crystalloid are used during cardiac surgery for priming of the cardiopulmonary bypass (CPB) circuit. Colloids may decrease postoperative fluid balance because of their high oncotic pressure and low risk of fluid extravasation. On the other hand, colloids have been shown to impair blood coagulation. Materials and methods: In a prospective, randomized, double-blinded study, 50 patients scheduled for coronary artery bypass grafting or a valve procedure were planned to be randomized to receive either balanced 6% HES130/0.42 or Ringer-acetate solution for CPB priming. Randomization was stopped prematurely after 35 randomized patients (19 in the HES and 16 in the Ringer groups) because of the published report where HES130/0.42 was associated with impaired renal function. Effects on haemostasis and fluid balance were investigated. Results: The rotational thromboelastometry (ROTEM®) parameters and chest tube drainage on the first postoperative morning (1POM) were comparable between the groups (p>0.05). However, patients in the HES group needed more blood and blood product transfusions. The total volume administered into the CPB circuit was lower in the HES than in the Ringer (RIN) group, 2905±1049 mL versus 3973±1207 mL (p=0.011), but there was no statistically significant difference in total fluid balance on the 1POM (5086±1660 mL in the HES group versus 5850±1514 mL in the RIN group, respectively). Conclusions: After complex cardiac surgery, the use of balanced 6% HES130/0.42 solution for CPB circuit priming did not impair haemostasis measured by ROTEM®, but it increased the need for transfusions. Fluid balance after CPB was less positive in the HES group, but, on the 1POM, it was comparable between the groups.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3