Anticoagulation monitoring during extracorporeal circulation with the Hepcon/HMS device

Author:

Noui N1,Zogheib E1,Walczak K1,Werbrouck A1,Amar A Ben2,Dupont H1,Caus T2,Remadi JP2

Affiliation:

1. Anesthesiology Unit, South Hospital, Amiens, France

2. Cardio-vascular Surgery Unit, University Hospital, CHU Amiens, France

Abstract

Objective: The objective of our study was to compare the standard protocol of anticoagulation to the Hepcon/HMS. Method: This study included forty-four patients who underwent coronary bypass grafting surgery (CABG), or biological aortic valve replacement (AVR). Unfractionated heparin (UH) was used for patients who underwent operations in the control group (n = 22) (300U/Kg of UH with a goal of an ACT of 400s). The heparin was antagonized dose/dose by protamine. For the patients who underwent operations in the HMS group (n = 22), the heparin and protamine doses were assessed by the Hepcon/HMS device. Results: The sex ratio amounted to 1.93 (29 men and 15 women) and the mean age was 70 ± 11 years. The patients in the HMS group had a chest closure time that was significantly shorter than patients in the control group. The times were, respectively, 42 ± 15 minutes and 68 ± 27 minutes (p = 0.001). The protamine/heparin ratio was significantly lower in the HMS group (0.62 ± 0.13 vs. 1 ± 0.11) (p = 0.0001). The postoperative bleeding amounted to 804 ± 729 ml in the HMS group versus 1416 ± 1103 in the control group (p = 0.016). In multivariate linear regression analysis, only two independent factors were significantly associated with bleeding: the Hepcon/HMS (OR = 0.1-p = 0.03) and the preoperative hemoglobin rate (OR = 1.4 - p = 0.05). Postoperatively, within 72 hours, the red blood cell transfusion was 1.04 ± 1.5 units for the HMS group and 2.1 ± 1.87 units for the control group (p = 0.05). Conclusion: During cardiac surgery under CPB, heparin and protamine titration with the Hepcon/HMS device could predict a lower protamine dose and lower postoperative bleeding without higher thromboembolic events, and lower perioperative red blood cell transfusion with a shorter chest closure time.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3