Protracted aortic valve closure during peripheral veno-arterial extracorporeal life support: is intra-aortic balloon pump an effective solution?

Author:

Meani Paolo12ORCID,Delnoij Thijs23,Raffa Giuseppe M.14ORCID,Morici Nuccia56,Viola Giovanna5,Sacco Alice5,Oliva Fabrizio5,Heuts Sam1,Sels Jan-Willem23,Driessen Rob23,Roekaerts Paul3,Gilbers Martijn1,Bidar Elham1,Schreurs Rick1,Natour Ehsan1,Veenstra Leo2,Kats Suzanne1,Maessen Jos1,Lorusso Roberto1

Affiliation:

1. Department of Cardio-Thoracic Surgery, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands

2. Cardiology, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands

3. Intensive Care Unit, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands

4. Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation and Department of Anesthesia and Intensive Care, IRCCS—ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy

5. De Gasperis Cardio Center, ASST Grande Ospedale Metropolitano Niguarda Ca’ Granda, Milan, Italy

6. Department of Clinical Sciences and Community Health, Università degli Studi, Milan, Italy

Abstract

Background: Left ventricular (LV) afterload increase with protracted aortic valve (AV) closure may represent a complication of veno-arterial extracorporeal membrane oxygenation (V-A ECMO). The aim of the present study was to assess the effects of an intra-aortic balloon pump (IABP) to overcome such a hemodynamic shortcoming in patients submitted to peripheral V-A ECMO. Methods: Among 184 adult patients who were treated with peripheral V-A ECMO support at Medical University Center Maastricht Hospital between 2007 and 2018, patients submitted to IABP implant for protracted AV closure after V-A ECMO implant were retrospectively identified. All clinical and hemodynamic data, including echocardiographic monitoring, were collected and analyzed. Results: During the study period, 10 subjects (mean age 60 years old, 80% males) underwent IABP implant after peripheral V-A ECMO positioning due to the diagnosis of protracted AV closure and inefficient LV unloading as assessed by echocardiography and an absence of pulsation in the arterial pressure wave. Recovery of blood pressure pulsatility and enhanced LV unloading were observed in 8 patients after IABP placement, with no significant differences in the main hemodynamic parameters, inotropic therapy or in the ECMO flow (p=0.48). The weaning rate in this patient subgroup (mean ECMO duration 8 days), however, was only 10%, with another patient finally transplanted, leading to a 20% survival-to-hospital discharge. Conclusion: IABP placement was an effective solution in order to reverse the protracted AV closure and impaired LV unloading observed during peripheral V-A ECMO support. However, the impact on the weaning rate and survival needs further investigations.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3