Evaluation of the Quadrox-I neonatal oxygenator with an integrated arterial filter

Author:

Salavitabar Arash1,Feng Qiu 1,Kunselman Allen2,Ündar Akif3

Affiliation:

1. Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, Pennsylvania, USA

2. Public Health and Sciences, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, Pennsylvania, USA

3. Department of Surgery, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, Pennsylvania, USA, Department of Bioengineering Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, Pennsylvania, USA,

Abstract

Cardiopulmonary bypass (CPB) can be a potential cause of morbidity in patients for several reasons, including significantly higher gaseous microemboli (GME) formation than extracorporeal life support (ECLS) and physiological circulation, diverted blood flow from the patient via an open purge line of the arterial filter, and pressure drop across the oxygenator that is used in the circuit. Using a combined oxygenator and arterial filter may minimize these harmful factors and can effectively reduce the chances for postoperative morbidity. This study investigated the new QUADROX-i Neonatal Oxygenator (D-72145, Maquet, Hirrlingen, Germany) with an integrated arterial filter in terms of the hemodynamic properties and ability to clear GME in response to hypothermic versus normothermic conditions, open versus closed arterial filter purge line, and varying flow rates in a simulated CPB circuit identical to that of the clinical setting. A flow probe, pressure transducer, and Emboli Detection and Classification (EDAC) quantifier transducer were placed upstream and downstream to the oxygenator to measure changes in each parameter. The circuit was primed with fresh human blood with an hematocrit (Hct) of 26% diluted with Ringer’s lactate solution. Five milliliters of air were injected proximal to the venous cardiotomy reservoir, under non-pulsatile perfusion, with flow rates of 500 ml/min, 750 ml/min, and 1000 ml/min. A total of 8 air bolus injections were made at each individual set of conditions for a total of 96 injections. Results showed that the QUADROX-i Neonatal Oxygenator with an integrated filter has excellent hemodynamic properties with extremely low pressure drops and blood flow diverted from the patient, as well as high rates of GME capturing. The arterial filter purge line has a significant effect on the degree of blood flow diverted from the patient (p < 0.001), but does not affect pressure drop across the oxygenator.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3