Active or passive bio-coating: does it matters in extracorporeal circulation?

Author:

Jacobs S1,De Somer F2,Vandenplas G2,Van Belleghem Y2,Taeymans Y2,Van Nooten G2

Affiliation:

1. Department of Anaesthesia, University Hospital Gent, Gent, Belgium

2. Heart Centre, University Hospital Gent, Gent, Belgium

Abstract

Background: Two types of surface coating for cardiopulmonary bypass (CPB) are used: bioactive (heparin, nitric oxide) and biopassive (albumin, polyethyleneoxide (PEO), phosphorylcholine). When haemocompatible coatings are combined with the separation of pleuro-pericardial aspiration, attenuation of both the coagulation and complement cascades, as well as better platelet preservation, has been demonstrated. This study wants to investigate if the combination of a bioactive with a biopassive coating (unfractionated heparin embedded in a phosphorylcholine matrix) combines the beneficial effects of both approaches. Materials and methods: Thirty patients undergoing elective CABG were prospectively randomized into two groups of 15 patients. The sole exclusion criterion was an ejection fraction of less than 40%. In the control group (PC), the whole CPB circuit was coated with phosphorylcholine (PC). In the study group (XPC), unfractionated heparin was embedded in the PC matrix of the oxygenator and arterial line filter. Results: No differences were found for haemolytic index, thrombin-anti-thrombin complex (TAT), IL-6, IL-10 and blood loss. PF4 plasma concentration increased from 27.6±22.0 IU/mL to 165.7±43.9 IU/mL (p<0.001) at 15 minutes of CPB in the PC and from 16.0±9.7 IU/mL to 150.9 ± 61.3 IU/mL (p<0.001) in the XPC group. Terminal complement complex (TCC) increased over time in both groups until the end of CPB (Figure 2A). Within each group, TCC generation was statistically significantly higher after the release of the aortic cross-clamp (p<0.001) and at the end of CPB (p<0.001). Total TCC generation was statistically significantly higher in the XPC group compared to the PC group (p=0.026). The difference was statistically significant after the release of the aortic cross-clamp (p=0.005) and at the end of CPB (p=0.001). Conclusions: Based on our results, there is no additional benefit in combining phosphorylcholine with unfractionated heparin in elective patients undergoing coronary artery bypass grafting (CABG). Massive haemodilution leads to enhanced complement activation.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3