Clinical performance of a high-efficiency rapid flow leucocyte removal filter for leucocyte depletion of heparinized cardiopulmonary bypass perfusate

Author:

Gu YJ1,deVries AJ2,Boonstra PW3,van Oeveren W.3

Affiliation:

1. Department of Cardiothoracic Surgery, University Hospital

2. Department of Anaesthesiology, University Hospital

3. Department of Cardiothoracic Surgery, University Hospital, Groningen

Abstract

The method of leucocyte depletion has been recently introduced to the field of cardiopulmonary bypass to reduce leucocyte-mediated organ dysfunction. In this study, we evaluated the efficacy and biocompatibility of the Pall RC400 filters for leucocyte depletion of heparinized cardiopulmonary bypass (CPB) perfusate taken from the heart-lung machine during routine cardiac surgery. For each filter, 700 ml blood were used as filtrate. Filtration was divided into the following groups to study the effect of loading pressure on the efficacy of the filters: under gravity pressure as a control (n = 8), under 100 mmHg (n = 8), 200 mmHg (n = 8), and 300 mmHg loading pressure (n = 8) driven by a roller pump. In addition, heparinized predonation blood taken at the beginning of CPB (n = 8) was filtered under gravity in comparison with the perfusate taken at the end of CPB. The results showed that the average leucocyte removal rate by an RC400 filter for 700 ml of blood was 96.8%. There was no significant difference of leucocyte removal rate between filtration under gravity and under loading pressure up to 300 mmHg. This allows clinical filtration at a speed up to 500 ml/min. The platelet removal rate was significantly higher in blood taken at the beginning of CPB than in blood taken at the end of CPB. Complement split product, C5a, increased only slightly during filtration indicating that this filter, made from polyester, has a good blood compatible characteristic. We conclude that the Pall RC400 leucocyte removal filter is suitable and safe to be used for leucocyte filtration of heparinized CPB perfusate during cardiac surgery.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Common Data Model-based Analysis of Selective Leukoreduction Protocol Compliance at Three Hospitals;Annals of Laboratory Medicine;2022-10-25

2. Engineering design of high-performance filter fabrics;Engineering of High-Performance Textiles;2018

3. Nonwoven fabric filters;Fibrous Filter Media;2017

4. Nonwoven fabric filters;Advances in Technical Nonwovens;2016

5. The potential of the novel leukocyte removal filter in cardiopulmonary bypass;Expert Review of Medical Devices;2015-12-19

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3