Prosthesis-prosthesis anastomosis using barbed sutures compared to conventional sutures under high, long-term pressure; in vitro extracorporeal circulation setup

Author:

Haenen Filip WN1ORCID,Van Oostende Claire2,Allegaert Mathias2,Round Kellen J3,Rosen Jake L3,Guy Sloane T4,Rodrigus Inez1

Affiliation:

1. Department of Cardiac Surgery, Antwerp University Hospital, Edegem, Belgium

2. Department of Anesthesia, Antwerp University Hospital, Edegem, Belgium

3. Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA

4. Division of Cardiac Surgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA

Abstract

Background While barbed sutures have been extensively utilized in other disciplines, they have not been widely adopted in cardiac surgery. The lack of safety and feasibility data has limited its use within the field. To aide in the further understanding of how cardiac surgeons can use barbed sutures, we sought to develop a high-pressure in vitro simulation model. We compared knotless barbed sutures in a highly pressurized anastomosis to conventional sutures. Methods Ten specimens in total were utilized in prosthesis anastomosis, using 34 mm Gelweave Plexus (Terumo Aortic, Sunrise, FL 33325, USA) and 34 mm Hemabridge (Intergard Woven Hemabridge, Getinge, Göteborg, Sweden). Five models of size 3-0 barbed suture anastomoses using non-absorbable, barbed, self-retaining, monofilament polypropylene sutures (Filbloc® 3-0, Assut Europe, Rome, Italy) were compared against five conventional anastomoses using size 4-0 polypropylene monofilament (Ethicon, USA). The systems were connected using a novel-designed extracorporeal circulation system. Pressure was rapidly increased in the specimen to a mean pressure of 300–350 mmHg, running then for a minimum of 48 hours to assess anastomosis strength and endurance. Results No anastomotic dehiscence or rupture was recorded. Complex, angular anastomosis required extra stitch leakage sutures in both conventional and barbed suture specimens. Conclusion Using knotless barbed sutures with an additional self-locking maneuver for prosthesis-prosthesis anastomosis in cardiac surgery is feasible in an in vitro model under long term, high-mean pressure when compared to conventional sutures. In vivo trials should be performed to further validate the in vitro findings.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Feasibility of Robotic Mitral Valve Repair Using Barbed Nonabsorbable Sutures: A Preliminary Single-Center Experience;Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery;2023-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3