Air removal capacity of two different minimal invasive ECC systems: an in vitro comparison

Author:

Stehouwer Marco C1ORCID,de Vroege Roel2

Affiliation:

1. Department of Extracorporeal Circulation, St Antonius Hospital, Nieuwegein, The Netherlands

2. Department of Extracorporeal Circulation, HAGA Hospital, The Hague, The Netherlands

Abstract

Minimally invasive extracorporeal circulation systems are developed to decrease the deleterious effects of cardiopulmonary bypass. For instance, prime volume and foreign surface area are decreased in these systems. However, because of the lack of a venous reservoir in minimized systems, air handling properties of these minimally invasive extracorporeal circulation systems may be decreased as compared to conventional cardiopulmonary bypass systems. The aim of this in vitro study is to compare the air handling properties of two complete minimized cardiopulmonary bypass systems of two manufacturers, of which one system is provided with the air purge control. In an in vitro study, two minimally invasive extracorporeal circulation systems, Inspire Min.I manufactured by Sorin Group Italia, Mirandola, Italy (LivaNova, London, United Kingdom) and minimized extracorporeal circulation manufactured by Maquet, Rastatt, Germany (Getinge, Germany), were challenged with two types of air challenges; a bolus air challenge and a gaseous microemboli challenge. The air removal characteristics of the venous bubble traps and of the complete minimally invasive extracorporeal circulation systems were assessed by measuring the gaseous microemboli volume and number downstream of the venous bubble traps in the arterial line with a bubble counter. No significant differences were observed in air reduction between the venous bubble traps of Getinge (venous bubble traps) and LivaNova (Inspire venous bubble traps 8 in conjunction with the air purge control). Similarly, no significant differences were observed in volume and number of gaseous microemboli in the arterial line of both complete minimally invasive extracorporeal circulation systems. However, the gaseous microemboli load of the Inspire Min.I system was marginally lower after both the bolus air and the gaseous microemboli challenges. Both minimally invasive extracorporeal circulation systems assessed in this study, the LivaNova Inspire Min.I and the Getinge minimized extracorporeal circulation, showed comparable air removal properties, after both bolus and gaseous microemboli air challenges. Besides, air purge control automatic air removal system provided with the LivaNova Inspire Min.I. system may enhance patient’s safety with the use of a minimally invasive extracorporeal circulation system. We consider both systems equally safe for clinical use.

Funder

livanova

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3