Clinical evaluation of the new BMU 40 in-line blood analysis monitor

Author:

Schaarschmidt Jan1,Seeburger Joerg2,Borger Michael A.2,Grosse F. Oliver3,Kraemer Klaus3,Mohr Friedrich W.2

Affiliation:

1. Department of Cardiovascular Perfusion, University of Leipzig - Heart Center, Germany,

2. Department of Cardiac Surgery, University of Leipzig - Heart Center, Germany

3. Department of Cardiovascular Perfusion, University of Leipzig - Heart Center, Germany

Abstract

Background: Accurate information about different blood parameters is essential in maintaining haemodynamics, perfusion and gas exchange during cardiopulmonary bypass (CPB). For this purpose, precise, accurate and continuous measurement and monitoring, preferably visually available, is needed.The objective of this clinical study was to compare the newly developed continuous in-line blood parameter monitoring system (CIBPMS) BMU 40 with a reference laboratory analyser with regards to the precision and accuracy of blood parameter measurement. Methods: Thirty adult patients underwent elective cardiac surgery, CPB and mild hypothermia (32°C). At five predetermined time points (S1 — S5) arterial and venous blood samples were analysed using the BMU 40 for five different parameters (PaO2(37°C), PaO2(act), SvO2, Hb(ven) and Hct(ven)) and these results were compared to the gold standard laboratory analyser, the ABL 700. Results: A total of 150 paired blood samples were included to compare means, to analyse correlation, and to calculate measures of bias, precision, limits of agreement and 95% confidence intervals. Results revealed good agreement between the two devices for all parameters. Bias ± precision of S2 — S5 PaO 2(37°C) were: 2.17 ± 9.61; PaO2(act) 2.58 ± 9.54; SvO2 -1.44 ± 2.35; Hb(ven) 0.01 ± 0.42; Hct(ven) 0.04 ± 1.29. Statistically significant differences were detected for SvO2 (p<0.00001) at S1. Correlations after this first time point (S1) improved following an in vivo calibration. Conclusion: The BMU 40 is a precise, accurate and reliable continuous in-line blood parameter measuring system that can easily be used within a standard CPB setup. However, present data suggest an in vivo calibration of the BMU 40 should be performed.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3