Effect of the adjunct of carbon dioxide during cardiopulmonary bypass on cerebral oxygenation

Author:

Quarti A1,Nardone S1,Manfrini F1,D’Orfeo F1,Genova S1,Silvano R1,Pozzi M1

Affiliation:

1. Congenital and Paediatric Cardiac Surgery and Cardiology, Azienda Ospedaliera Ospedali Riuniti, Ancona, Italy

Abstract

Introduction: Over the last few years, near-infrared spectroscopy (NIRS) has been introduced to study cerebral haemodynamics and oxygenation. This paper points out how the use of an external source of CO2 effects on the absolute value of cerebral NIRS during cardiac surgery on cardiopulmonary bypass. Patients and methods: Between January 2010 and September 2011, 368 patients underwent congenital heart disease correction on cardiopulmonary bypass (CPB). Nineteen patients, with a mean age of 26 days (range 6-120 days), required an external source of CO2 to correct hypocarbia during cardiopulmonary bypass. Different parameters were monitored: NIRS value, oxygen saturation, oxygen partial pressure, CO2 partial pressure, haematocrit, mean arterial pressure and pH. They were analyzed during different phases of the surgical procedure: before, during and after CO2 infusion. Results: There were no deaths during the hospital stay. The NIRS value increased significantly (p<0.05) after the addition of CO2, from a starting value of 52.9 to a final value of 63.4. PaCO2 was found to increase too: from 31.3 mmHg to 40.6 mmHg. On the other hand, both values decreased when the CO2 was removed, to respective final values of 55.8 and 34.4 mmHg. Mean arterial pressure, haematocrit and PaO2 didn’t modify significantly during this period. Conclusions: Nowadays, NIRS is usually used in cardiac surgery to reduce possible risks of neurological damage. The importance of the role of pCO2 in the cerebral vascular resistance and in cerebral blood flow has already been proven. This research demonstrates a relationship between pCO2 and the NIRS value. This paper could introduce an important correcting tool when an inadequate NIRS value occurs although the level of oxygenation, haematocrit and mean arterial pressure are acceptable and the arterial line is accurately positioned.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3