Microembolism during cardiopulmonary bypass: a comparison of bubble oxygenator with arterial line filter and membrane oxygenator alone

Author:

Griffin Steven1,Pugsley Wilfred1,Treasure Tom1

Affiliation:

1. Department of Cardiothoracic Surgery, Middlesex Hospital, London

Abstract

Microemboli can be detected in the cerebral circulation during cardiopulmonary bypass with transcranial Doppler. They are likely to be responsible for the microvascular occlusions that have been seen in the retina and they may contribute to neuropsychological damage that has been demonstrated after cardiac surgery. Twenty patients undergoing routine coronary artery bypass graft surgery were allocated to either a Harvey 1700 bubble oxygenatorwith a Pall 40μ arterial line filter or a Harvey 4000 membrane oxygenator with no arterial line filter. All cases received pulsatile flow perfusion with core cooling to 28°C. A standard surgical technique was used with distal anastomoses performed during cold cardioplegic arrest and proximal anastomoses performed with coronary perfusion during systemic rewarming. Microembolic events were measured by the counting of flow disturbances over the pattern of pulsatile flow as detected by Doppler. Median bypass time was 69 minutes (range 45-95) for the bubbler group and 79 minutes (range 50-115) for the membrane group. The microembolic event count was normalized to the number of events per 15 minute period of bypass. The median number of microembolic events per 15 minute period of bypass was 28 (range 6-54) for the bubble group and 21 (range 10-65) for the membrane group. There were no significant differences between the lengths of bypass between the two groups (Mann-Whitney p = 0.202) or the number of microemboli recorded per 15 minute period of bypass (Mann-Whitney p = 0.224). We conclude that the previously demonstrated excess generation of gaseous microemboli from bubble oxygenators over membrane oxygenators is negated by the use of a 40μ arterial line filter with the bubble oxygenator.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3