Use of an intravascular gas exchanger: is low systemic heparinization safe?

Author:

von Segesser LK1,Pasic M.1,Tönz M.1,Lachat M.1,Leskosek B.1,Turina MI1

Affiliation:

1. Clinic for Cardiovascular Surgery, University Hospital, Zürich

Abstract

Extracorporeal membrane oxygenation (ECMO) is a cumbersome procedure. Alternatively, mechanical lung assist can be realized with an intravascular gas exchanger (IVOX). To assess the degree of initial anticoagulation required during intravascular lung assist, we evaluated two regimens of systemic heparinization in 10 bovine experiments. The animals were randomly assigned to two groups with either full systemic heparinization (heparin loading dose 300 IU/kg bodyweight; activated coagulation time (ACT) > 480 s) or low systemic heparinization (heparin loading dose 100 IU/kg bodyweight; ACT > 180 s). The surface heparinized intravascular gas exchanger was placed in the caval axis under fluoroscopic control, and a standard battery of blood samples was drawn before and at regular intervals during the procedure. After six hours of intravascular lung assist the device was explanted, drained, weighed, and carefully analysed. Preassist haematocrit was 25 ± 5% for full versus 24 ± 7% for low (NS) as compared with 23 ± 8% for full versus 26 ± 3% for low (NS) postassist. Platelet levels were 100 ± 25 for full versus 100 ± 21 % for low (NS) preassist as compared with 64 ± 22% for full versus 78 ± 22% for low (NS) postassist. Mean ACT was 157 ± 12 s for full versus 158 ± 18 for low (NS) preassist as compared with 800 ± 244 s versus 219 ± 25 for low (p < 0.05) postassist. Thrombin time was 20 ± 2 s for full versus 23 ± 2 s for low (NS) as compared with > 200 s for both groups after assist. Relative fibrinopeptide A levels were 7.3 ± 1.1 ng/ml for full versus 6.3 ± 1.6 ng/ml for low (NS) preassist as compared with 4.7 ± 4.1 ng/ml for full versus 5.8 ± 0.9 ng/ml for low (NS) postassist. CO2 transfer was 40 ± 10 ml/min for full versus 36 ± 10 ml/min for low (NS) at the begining as compared with 45 ± 25 ml/min for full versus 46 ± 15 for low (NS) at the end. Weight increase due to device deposits (clots) was 14 ± 11 g for full versus 13 ± 10 g for low systemic heparinization (NS). Intravascular lung assist with low versus full systemic heparinization appeared to result in similar activation of the coagulation system, device deposits and gas transfer rates. Considering our clinical experience we can say that application of the device with reduced systemic heparinization is useful in selected patients.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3