Discussion: can upper extremity (deltoid) near infrared spectroscopy be used to assess cerebral tissue bed saturation on femorally cannulated veno-arterial extracorporeal membrane oxygenation patients?

Author:

Beck James R1ORCID,Holt David W2,Chan Christine1,Fung Kenmond1,Patton-Rivera Killian1ORCID,Mullin Dana1,Takeda Koji1,Takayama Hiroo1

Affiliation:

1. Division of Cardiothoracic Surgery and Clinical Perfusion, Department of Surgery, New York Presbyterian Hospital, Columbia University Irving Medical Center, New York, NY, USA

2. Clinical Perfusion Education, University of Nebraska Medical Center, Omaha, NE, USA

Abstract

Continuous cerebral tissue saturation monitoring with near infrared spectroscopy may help clinicians identify cerebral desaturation early; however, patients have reported discomfort from near infrared spectroscopy monitoring pads on the forehead. This study aims to compare upper extremity near infrared spectroscopy monitoring to cerebral near infrared spectroscopy monitoring to assess its viability as a surrogate for cerebral saturation. A retrospective analysis of 10 femorally cannulated veno-arterial extracorporeal membrane oxygenation patients was performed comparing left (L) and right (R) upper extremity (deltoid) near infrared spectroscopy monitoring to cerebral near infrared spectroscopy monitoring (n = 20 data sets, 10 left and 10 right) and right radial blood gasses. Deltoid and cerebral near infrared spectroscopy values were recorded every 15 minutes for at least 24 hours when possible, were plotted on scatter grams, and were analyzed using Pearson product-moment coefficient (r). Based on the concept of covariance, a moderate-good relationship r = 0.50-0.75 was noted in 10% (n = 2) of the study group. A fair relationship r = 0.25-0.50 was noted in 50% (n = 10), and little or no relationship was noted in 40% (n = 8). None of the study group displayed a good to excellent relationship (r = 0.75 or above). In addition, coefficient of multiple determination for multiple regression R2 was calculated and strong fit of the regression line was not noted. Although cerebral near infrared spectroscopy monitoring has been extremely helpful in identifying low cerebral tissue saturation on veno-arterial extracorporeal membrane oxygenation patients, the use of upper extremity (peripheral deltoid) tissue monitoring does not provide adequate correlation and should not be used as a surrogate to cerebral monitoring.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Cardiogenic Shock Management Should Be a Team Sport;Journal of the American College of Cardiology;2021-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3