Clinical experience with Affinity Pixie™ oxygenation system in paediatric and infant patients

Author:

Issitt R1,Robertson A1,Cross N1,Crook R1,Molyneux V1,Shaw M1,Walton N1,Tsang V2

Affiliation:

1. Department of Clinical Perfusion Great Ormond Street Children’s Hospital, London, UK

2. Department of Paediatric Cardiothoracic Surgery, Great Ormond Street Children’s Hospital, London, UK

Abstract

Introduction: Great Ormond Street Children’s Hospital undertakes over 500 open heart cardiothoracic procedures requiring cardiopulmonary bypass per year. Data from our centre show that many of our neonatal/paediatric patients require higher cardiac indexes than previously thought. We evaluated the new Pixie™ oxygenation system, rated from 0.1 L/min to 2 L/min, to determine if it could be used for these patients. Methods: Between 2010 and 2012, 250 Pixie™ oxygenators were used on consecutive patients requiring correction of congenital cardiac defects. Data were collected on FiO2 requirements, oxygenator pressure drop and gaseous microemboli handling. Retrospective analysis was also undertaken on the procedures and demographics of all patients during 2011-2012 to determine the percentage of patients on whom the Pixie™ could be used. Results: Analysis of the procedures undertaken at Great Ormond Street Hospital (GOSH) showed that 89% were in patients under 20 kg, requiring a flow rate of <2 L/min (at a base cardiac index of 2.8 L/min/m2). The maximum FiO2 required at 2.5 L/min was 85%. Gaseous microemboli were reduced by 82.5±9.9% and bubble volume was decreased by 94.3±8.4% from the ‘venous’ pre-oxygenator to the ‘arterial’ post-oxygenator. Discussion: The Pixie™ oxygenator proved effective at flows up to 2.5 L/min, with air-handling capabilities comparable with other oxygenators. This represents a single oxygenator that could potentially be used to cover 89% of our surgical procedures. However, we believe that, for the smallest patients (i.e. < 2kg), a smaller priming oxygenator should be used in order to limit unnecessary haemodilution in this vulnerable group.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3