Coagulation monitoring correlation with heparin dose in pediatric extracorporeal life support

Author:

Moynihan Katie123,Johnson Kerry1,Straney Lahn4,Stocker Christian1235,Anderson Ben5,Venugopal Prem5,Roy John36

Affiliation:

1. Pediatric Intensive Care Unit, Lady Cilento Children’s Hospital (LCCH), Brisbane, Australia

2. Pediatric Critical Care Research Group, LCCH, Brisbane, Australia

3. University of Queensland School of Medicine, Brisbane, Australia

4. Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, Australia

5. Queensland Neonatal & Pediatric ECLS Service, LCCH, Brisbane, Australia

6. Pathology Queensland, Brisbane, Australia

Abstract

Objectives: Extracorporeal Life Support (ECLS) risks thrombotic and hemorrhagic complications. Optimal anti-coagulation monitoring is controversial. We compared coagulation tests evaluating the heparin effect in pediatric ECLS. Methods: A retrospective study of children (<18yrs) undergoing ECLS over 12 months in a tertiary pediatric intensive care unit (PICU). Variables included anti-Factor Xa activity (anti-Xa), activated partial thromboplastin time (aPTT), activated clotting time (ACT) and thromboelastogram (TEG®6s) parameters: ratio and delta reaction (R) times (the ratio and difference, respectively, between R times in kaolin assays with and without heparinase). Test results were correlated with unfractionated heparin infusion rate (IU/kg/hr) at the time of sampling. Mean test results of each ECLS run were evaluated according to the presence/absence of complications. Results: Thirty-two ECLS runs (31 patients) generated 695 data-points for correlation. PICU mortality was 22% and the thrombotic complication rate was 66%. The proportion of variation in coagulation test results explained by heparin dose was 13.3% for anti-Xa, 11.9% for ratio R time, and 9.9% for delta R time, compared with <1% for ACT and aPTT. Incorporating individual variation, age and antithrombin activity in a model with heparin dose explained less than 50% of the variation in test results. Correlation varied according to age, day of ECLS run and between individuals, with parallel dose-response lines noted between patients. Significantly lower mean anti-Xa was observed in PICU non-survivors and runs with thrombosis. Conclusion: Lower anti-Xa was observed in ECLS runs with complications. Although absolute results from anti-Xa and TEG6®s showed the best correlation with heparin dose, a large proportion of variation in results was unexplained by heparin, while dose response was similar between individuals. Population pharmacokinetic/pharmacodynamic modelling is required, as well as prospective trials to delineate the superior means of adjusting heparin therapy to prevent adverse clinical outcomes.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3