Amplitude Compression for Preventing Rollover at Above-Conversational Speech Levels

Author:

Fereczkowski Michal12ORCID,Sanchez-Lopez Raul H.3ORCID,Christiansen Stine12,Neher Tobias12ORCID

Affiliation:

1. Institute of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark

2. Research Unit for ORL – Head & Neck Surgery and Audiology, Odense University Hospital & University of Southern Denmark, Odense, Denmark

3. Interacoustics Research Unit, Kongens Lyngby, Denmark

Abstract

Hearing aids provide nonlinear amplification to improve speech audibility and loudness perception. While more audibility typically increases speech intelligibility at low levels, the same is not true for above-conversational levels, where decreases in intelligibility (“rollover”) can occur. In a previous study, we found rollover in speech intelligibility measurements made in quiet for 35 out of 74 test ears with a hearing loss. Furthermore, we found rollover occurrence in quiet to be associated with poorer speech intelligibility in noise as measured with linear amplification. Here, we retested 16 participants with rollover with three amplitude-compression settings. Two were designed to prevent rollover by applying slow- or fast-acting compression with a 5:1 compression ratio around the “sweet spot,” that is, the area in an individual performance-intensity function with high intelligibility and listening comfort. The third, reference setting used gains and compression ratios prescribed by the “National Acoustic Laboratories Non-Linear 1” rule. Speech intelligibility was assessed in quiet and in noise. Pairwise preference judgments were also collected. For speech levels of 70 dB SPL and above, slow-acting sweet-spot compression gave better intelligibility in quiet and noise than the reference setting. Additionally, the participants clearly preferred slow-acting sweet-spot compression over the other settings. At lower levels, the three settings gave comparable speech intelligibility, and the participants preferred the reference setting over both sweet-spot settings. Overall, these results suggest that, for listeners with rollover, slow-acting sweet-spot compression is beneficial at 70 dB SPL and above, while at lower levels clinically established gain targets are more suited.

Funder

Innovation Fond Denmark

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3