Effects of Tinnitus on Cochlear Implant Programming

Author:

Pierzycki Robert H.12ORCID,Corner Charlotte12,Fielden Claire A.13,Kitterick Pádraig T.123ORCID

Affiliation:

1. National Institute for Health Research Nottingham Biomedical Research Centre, UK

2. Hearing Sciences, Division of Clinical Neuroscience, School of Medicine, University of Nottingham, UK

3. Nottingham University Hospitals National Health Service Trust, Queen’s Medical Centre, UK

Abstract

Clinical observations suggest that tinnitus may interfere with programming cochlear implants (CIs), the process of optimizing the transmission of acoustic information to support speech perception with a CI. Despite tinnitus being highly prevalent among CI users, its effects and impact on CI programming are obscure. This study characterized the nature, time-course, and impact of tinnitus effects encountered by audiologists and patients during programming appointments. Semistructured interviews with six CI audiologists were analyzed thematically to identify tinnitus effects on programming and related coping strategies. Cross-sectional surveys with 67 adult CI patients with tinnitus and 20 CI audiologists in the United Kingdom examined the prevalence and time-course of those effects. Programming parameters established at CI activation appointments of 10 patients with tinnitus were compared with those of 10 patients without tinnitus. On average, 80% of audiologists and 45% of patients reported that tinnitus makes measurements of threshold (T) levels more difficult because patients confuse their tinnitus with CI stimulation. Difficulties appeared most common at CI activation appointments, at which T levels were significantly higher in patients with tinnitus. On average, 26% of patients reported being afraid of “loud” CI stimulation worsening tinnitus, affecting measurements of loudest comfortable (C) stimulation levels, and 34% of audiologists reported observing similar effects. Patients and audiologists reported that tinnitus makes programming appointments more difficult and tiresome for patients. The findings suggest that specific programming strategies may be needed during CI programming with tinnitus, but further research is required to assess the potential impact on outcomes including speech perception.

Funder

Nottingham Hospitals Charity

Publisher

SAGE Publications

Subject

Speech and Hearing,Otorhinolaryngology

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3