New patient-controlled abdominal compression method in radiography: radiation dose and image quality

Author:

Piippo-Huotari Oili1,Norrman Eva2,Anderzén-Carlsson Agneta3,Geijer Håkan4ORCID

Affiliation:

1. Department of Radiology, Faculty of Health Sciences, Örebro University, Örebro, Sweden

2. Department of Medical Physics, Faculty of Medicine and Health, Örebro University, Örebro, Sweden

3. University Health Care Research Center, Faculty of Medicine and Health, Örebro University, Örebro, Sweden

4. Department of Radiology, Faculty of Medicine and Health, Örebro University, Örebro, Sweden

Abstract

Background The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position . Purpose To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. Material and Methods An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. Results There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. Conclusion Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

Funder

Örebro Universitet

The Research Committee of Region Örebro County, Sweden

Publisher

SAGE Publications

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3