Use of 0.014-in. pushable bare platinum coils in super-selective embolization through the 1.6-Fr. microcatheter of the triaxial system

Author:

Tsukahara Satoshi1ORCID,Shimohira Masashi2ORCID,Nagai Keiichi2,Ohta Kengo2,Sawada Yusuke2,Hashizume Takuya3,Goto Taeko4,Shibamoto Yuta2

Affiliation:

1. Department of Radiology, Kariya Toyota General Hospital, Kariya, Japan

2. Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan

3. Department of Radiology, Nagoya Kyoritsu Hospital, Nagoya, Japan

4. Department of Radiology, Ichinomiya Municipal Hospital, Ichinomiya, Japan

Abstract

Background A triple-coaxial (triaxial) system, which consists of a small microcatheter, a large microcatheter, and a 4-Fr. catheter, has been reported to allow super-selective catheterization. A 1.6-Fr. microcatheter has recently become available as the small microcatheter for the triaxial system, in addition to 0.014-in. pushable bare platinum coils that may be introduced into the 1.6-Fr. microcatheter. Purpose The purpose of the present study was to evaluate the feasibility of 0.014-in. pushable bare platinum coils in embolization through the 1.6-Fr. microcatheter of the triaxial system. Material and Methods Between November 2015 and October 2019, 19 embolizations were performed on 18 patients, 9 males and 9 females with a median age of 77 years (range, 41–88 years), using 0.014-in. pushable bare platinum coils through the 1.6-Fr. microcatheter of the triaxial system. The technical success rate, clinical success rate, and complications associated with the procedure were assessed. Technical success was defined as the successful delivery and placement of 0.014-in. pushable bare platinum coils, and clinical success as the immediate postembolic complete cessation of blood flow confirmed by digital subtraction angiography. Results Eighty-four 0.014-in. pushable bare platinum coils were delivered and 19 arteries were successfully embolized. The median number of 0.014-in. pushable bare platinum coils was 4 (range, 1–12). The technical success rate was 100% (84/84) and the clinical success rate was also 100% (19/19). There were no complications associated with the procedures. Conclusion The use of 0.014-in. pushable bare platinum coils in super-selective embolization through the 1.6-Fr. microcatheter of the triaxial system appears to be feasible and safe.

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. MICRO ACTIVE CATHETERS AND EMBOLIZATION TECHNIQUES: A BRIEF REVIEW BASED ON DESIGN AND WORKING EFFICACY;Biomedical Engineering: Applications, Basis and Communications;2022-05-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3