Assessment of microbial bioburden on portable medical equipment in a hospital setting

Author:

Chatterjee Piyali1,Coppin John David1,Martel Julie Ann1,Williams Marjory D1,Choi Hosoon1,Stibich Mark2,Simmons Sarah2,Passey Deborah3,Allton Yonhui1,Jinadatha Chetan1ORCID

Affiliation:

1. Central Texas Veterans Health Care System, Temple, TX, USA

2. Xenex Disinfection Services, San Antonio, TX, USA

3. University of Utah, Salt Lake City, UT, USA

Abstract

Objectives: Although routine disinfection of portable medical equipment is required in most hospitals, frontline staff may not be able to disinfect portable medical equipment at a rate that adequately maintains low bioburden on high-use equipment. This study quantified bioburden over an extended time period for two types of portable medical equipment, workstations on wheels and vitals machines, across three hospital wards. Methods: Bioburden was quantified via press plate samples taken from high touch surfaces on 10 workstations on wheels and 5 vitals machines on each of 3 medical surgical units. The samples were taken at three timepoints each day over a 4-week period, with random rotation of timepoints and portable medical equipment, such that frontline staff were not aware at which timepoint their portable medical equipment would be sampled. The mean bioburden from the different locations and portable medical equipment was estimated and compared with Bayesian multilevel negative binomial regression models. Results: Model estimated mean colony counts (95% credible interval) were 14.4 (7.7–26.7) for vitals machines and 29.2 (16.1–51.1) for workstations on wheels. For the workstations on wheel, colony counts were lower on the mouse, 0.22 (0.16–0.29), tray, 0.29 (0.22, 0.38), and keyboard, 0.43 (0.32–0.55), when compared to the arm, as assessed by incident rate ratios. Conclusions: Although routine disinfection is required, bioburden is still present across portable medical equipment on a variety of surfaces. The difference in bioburden levels among surfaces likely reflects differences in touch patterns for the different portable medical equipment and surfaces on the portable medical equipment. Although the association of portable medical equipment bioburden to healthcare-associated infection transmission was not assessed, this study provides evidence for the potential of portable medical equipment as a vector for healthcare-associated infection transmission despite hospital disinfection requirements.

Funder

NIH NINR

Publisher

SAGE Publications

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3