Heartware ventricular assist device versus HeartMate II versus HeartMate III in advanced heart failure patients: A systematic review and meta-analysis

Author:

Hanafy Dudy Arman12ORCID,Husen Theresia Feline3,Angelica Ruth3,Nathania Ilona1,Trianita Suwatri Widya12,Lintangella Pasati1,Erdianto Wahyu Prima1,Prasetyo Prisillia1

Affiliation:

1. Division of Cardiothoracic and Vascular Surgery, Department of Surgery, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia

2. Division of Adult Cardiac Surgery, Department of Surgery, National Cardiovascular Center, Harapan Kita, Jakarta, Indonesia

3. Faculty of Medicine, University of Indonesia, Pondok Cina, Beji, Depok City, West Java, Indonesia

Abstract

Objective: Ventricular assist device is one of the treatment options for heart failure patients. Therefore, the purpose of this review is to aid in clinical decision-making of exchanging previous older ventricular assist device models to the newest one, HM3. Methods: The search was conducted across several databases until February 25, 2023, and was registered with the ID of CRD42023405367. Risk of bias was performed using Cochrane Risk of Bias 2.0 and the Newcastle Ottawa Scale. In order to rank and evaluate the pooled odds ratios and mean differences with 95% confidence intervals, we employed conventional and Bayesian network meta-analysis converted to surface under the cumulative ranking. Results: A total of 49 studies with 31,105 patients were included in this review. HM3 is the best device exchange choice that causes the lowest risk of mortality (HM3 (99.98) > HM2 (32.43) > HVAD (17.58)), cerebrovascular accidents (HM3 (99.99) > HM2 (42.41) > HVAD (7.60)), other neurologic events beside cerebrovascular accident (HM3 (91.45) > HM2 (54.16) > HVAD (4.39)), pump thrombosis (HM3 (100.00) > HM2 (39.20) > HVAD (10.80)), and bleeding (HM3 (97.12) > HM2 (47.60) > HVAD (5.28)). HM3 is also better than HM2 in hospital admissions (OR: 1.90 (95% CI: 1.15–3.12)). When complications were present, HM2 or Heartware ventricular assist devices exchange to HM3 lowered the mortality rate compared to exchanging it to the same device type. Conclusion: HM3 is the best device for all six outcomes. Exchange from Heartware ventricular assist devices or HM2 to HM3 rather than the same ventricular assist device type is recommended only if a complication is present.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3