Performance analysis of a liquid desiccant system with an adjustable reflux ratio of regeneration solution

Author:

Niu Xiaofeng1,Zhang Yue1,Li Xing1,Tong Yan1,Zhang Guangli1

Affiliation:

1. College of Urban Construction, Nanjing Tech University, Nanjing, China

Abstract

In the liquid desiccant system, the amount of the diluted solution sent to the regenerator has a great influence on the system performance. The liquid desiccant system with an adjustable reflux ratio of regeneration solution was proposed in the paper, and the effect of the solution regeneration reflux ratio on the system performance was analysed by simulation. The energy consumption, the electric coefficient of performance and the thermal coefficient of performance under different water condensation rates and varied solution regeneration reflux ratio were obtained. The results show that, the overall performance of the liquid desiccant system can be improved by reducing the solution regeneration reflux ratio; a 1% decrease in the reflux ratio leads to a 0.56–1.02% average growth rate of electric coefficient of performance and a 0.51–0.95% average growth rate of thermal coefficient of performance. Moreover, when the regeneration temperature is high and the water condensation rate of the process air is low, the improvement from decreasing the solution regeneration reflux ratio is more significant. However, the reflux ratio cannot be reduced to an unlimited extent. There is a rational optimum range of the reflux ratio to achieve high thermal coefficient of performance, the optimum range under low dehumidifying load is different from that under high load. Practical application: The performance of a liquid desiccant system can be improved by the proposed system configuration with an adjustable reflux ratio of regeneration solution, such novel system configuration could be applied for the design of air conditioning system, which is beneficial for the energy saving in building. Moreover, the rational optimum ranges of the reflux ratio to achieve high coefficient of performance under different dehumidifying loads are obtained, which could provide guidelines for the design and operation management of the liquid desiccant based building air conditioning system.

Publisher

SAGE Publications

Subject

Building and Construction

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3