Modelling and economic optimisation of under-floor heating system

Author:

Sanaye Sepehr1,Mahmoudimehr Javad1,Aynechi Mohsen1

Affiliation:

1. Energy Systems Improvement Laboratory, School of Mechanical Engineering, Iran University of Science and Technology, Iran

Abstract

Modelling and optimisation of the under-floor heating system (UFHS) with Pex pipes are studied in this paper. For modelling the system, two regions were considered. The first one was the over-floor region which included room air and walls. This region was considered as one control volume and the system of non-linear energy equations for room air and walls were solved using Newton–Raphson method. The second or under-floor region included heating pipes, concrete and floor finish. This region was modelled using finite volume method. For optimising the UFHS, an objective function (sum of investment and operating costs of UFHS) was proposed and type and thickness of the floor finish, velocity of hot water passing through the pipe, concrete thickness and pipe diameter, were considered as the decision variables (design parameters). The sensitivity analysis showed 19.8%, 10.5%, 2.8% and 0.3% increase in the objective function with the deviation of the four above-mentioned design parameters from their optimum values (floor finish from tile to marble, water velocity from 1.5 to 2.5 m/s, concrete thickness from 6 to 8 cm and pipe diameter from ½ to ¾ in.). Finally, with the decrease in external temperature from −10°C to −20°C, the objective function increased by 21.7% and the required floor heat flux increased by 33.1%. Increasing the insulation thickness from 2.5 to 7 cm also decreased the objective function by 20.5% and decreased the required floor heat flux by 38.5%. Practical application: A new and fast combined numerical and analytical procedure for thermal modelling of UFHS was proposed in this paper. By applying the proposed modelling procedure, the optimum values of UHFS design parameters for reaching the system lowest cost were obtained. The variation of total cost with deviation of design parameters from their optimum values was investigated. The effects of change in atmospheric temperature and wall insulation thickness on building thermal load and the total cost were studied.

Publisher

SAGE Publications

Subject

Building and Construction

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3